appendix1‑8
35
Analog monitor gain #2
This parameter is used for monitoring signals by the analog monitor card (optional).
Specifies the monitoring gain scale factor of the analog monitor #2.
If the specified scaling value is 'n', then:
+/‑3.07V vs +/‑2^n
2^n will result in an amplitude of +/‑ 3.07V on the velocity monitor
The maximum amplitude voltage is +/‑4.80V.
8
24
8
Min:
Max:
Initial:
Unit:
A̲Mon2Gain
Dec
36
Digital monitor select #1
This parameter is used for monitoring signals by the analog monitor card (optional).
Selects item to be output to the digital monitor #1. Specify the paramter monitor number and bit
number to be observed.
Bit 16 ‑ 8 Parameter monitor number
Bit 4 ‑ 0 Bit number
−
−
depend on motor.driver type
Min:
Max:
Initial:
Unit:
Initial value: State when H00014010 #320 bit16 is selected
D̲Mon1Sel
Hex
37
Digital monitor select #2
This parameter is used for monitoring signals by the analog monitor card (optional).
Selects item to be output to the digital monitor #2. Specify the paramter monitor number and bit
number to be observed.
Bit 16 ‑ 8 Parameter monitor number
Bit 4 ‑ 0 Bit number
−
−
depend on motor.driver type
Min:
Max:
Initial:
Unit:
Initial value: State when H00014000A #320 bit10 is selected
D̲Mon2Sel
Hex