SIPROTEC
®
4 Devices
4-2
7SA6 Manual
C53000-G1176-C156-2
4.1
General
The SIPROTEC
®
4 family is an innovative product series of numerical protective and
control devices with open communication interfaces for remote control and remote
setting, ergonomically designed operator panels, and highly flexible functionality.
4.1.1
Protection and Control
The devices utilize numerical measuring techniques. Complete numerical signal
processing offers high measurement accuracy and long-term consistency, as well as
reliable handling of harmonics and transients. Digital filtering techniques and adaptive
stabilization of measured values ensure the highest security in establishing the devic-
es’ correct responses. Device errors are recognized and quickly annunciated by inte-
grated self-monitoring routines. Failure of protection during a fault is therefore almost
entirely prevented.
You may choose devices with separate protective and process control functions, or
select a solution that implements both requirements.
The following solutions are available:
G
Protection and control in separate devices,
G
Protective devices that provide the capability to control the circuit breaker or primary
switching device through a communication interface,
G
Devices with combined features that, in addition to protective functions, allow on-
site operation for several circuit breakers and primary switching devices and that
provide extensive substation control functions.
4.1.2
Communication
SIPROTEC
®
4 devices are completely suited for the requirements of modern commu-
nication technology. They have interfaces that allow for integration into higher-level
control centres, and user friendly operation through an on-site PC or via a modem con-
nection. Simple, comfortable device setup and operation are provided.
SIPROTEC
®
4 devices support the widespread, internationally accepted communica-
tion standards
G
IEC 60870-5-103,
G
PROFIBUS FMS,
G
DNP 3.0 Level 2,
G
MODBUS ASCII/RTU,
G
PROFIBUS DP and
G
UCA II / Ethernet (future)
Содержание siprotec 7SA6
Страница 2: ...Siemens Aktiengesellschaft Book No C53000 G1176 C156 2 ...
Страница 18: ...xviii 7SA6 Manual C53000 G1176 C156 2 ...
Страница 32: ...Introduction 1 14 7SA6 Manual C53000 G1176 C156 2 ...
Страница 82: ...Hardware and Connections 2 50 7SA6 Manual C53000 G1176 C156 2 ...
Страница 119: ...SIPROTEC 4 Devices 4 25 7SA6 Manual C53000 G1176 C156 2 Figure 4 20 CFC Logic example ...
Страница 190: ...Configuration 5 62 7SA6 Manual C53000 G1176 C156 2 ...
Страница 559: ...Control During Operation 7 45 7SA6 Manual C53000 G1176 C156 2 Figure 7 45 Circuit breaker trip test in DIGSI 4 ...
Страница 652: ...Installation and Commissioning 8 78 7SA6 Manual C53000 G1176 C156 2 ...
Страница 724: ...Technical Data 10 56 7SA6 Manual C53000 G1176 C156 ...
Страница 800: ...Appendix A 76 7SA6 Manual C53000 G1176 C156 2 ...
Страница 866: ...Appendix B 66 7SA6 Manual C53000 G1176 C156 2 ...