Appendix
B-30
7SA6 Manual
C53000-G1176-C156-2
1253
>Block sensitive E/F detection (>SensEF
block)
Sensitive Earth
Flt.(comp/ isol.
starp.)
SP
*
*
LED BI
BO
1260
Sensitve E/F detection ON/OFF via BI
(SensEF on/offBI)
Sensitive Earth
Flt.(comp/ isol.
starp.)
IntSP
ON
OFF
*
LED
BO
1261
Sensitve E/F detection is switched OFF
(SensEF OFF)
Sensitive Earth
Flt.(comp/ isol.
starp.)
OUT
ON
OFF
*
LED
BO
151 161 1
GI
1262
Sensitve E/F detection is BLOCKED
(SensEF BLOCK)
Sensitive Earth
Flt.(comp/ isol.
starp.)
OUT
ON
OFF
ON
OFF
LED
BO
151 162 1
GI
1263
Sensitve E/F detection is ACTIVE
(SensEF ACTIVE)
Sensitive Earth
Flt.(comp/ isol.
starp.)
OUT
ON
OFF
*
LED
BO
151 163 1
GI
1271
Sensitve E/F detection picked up (SensEF
Pickup)
Sensitive Earth
Flt.(comp/ isol.
starp.)
OUT
*
ON
OFF
*
M
LED
BO
1272
Sensitve E/F detection Phase L1 (SensEF
Phase L1)
Sensitive Earth
Flt.(comp/ isol.
starp.)
OUT
*
*
ON
LED
BO
128 48
1
GI
1273
Sensitve E/F detection Phase L2 (SensEF
Phase L2)
Sensitive Earth
Flt.(comp/ isol.
starp.)
OUT
*
*
ON
LED
BO
128 49
1
GI
1274
Sensitve E/F detection Phase L3 (SensEF
Phase L3)
Sensitive Earth
Flt.(comp/ isol.
starp.)
OUT
*
*
ON
LED
BO
128 50
1
GI
1276
Sensitve E/F detection Forward (SensEF
Forward)
Sensitive Earth
Flt.(comp/ isol.
starp.)
OUT
*
*
ON
LED
BO
128 51
1
GI
1277
Sensitve E/F detection Reverse (SensEF
Reverse)
Sensitive Earth
Flt.(comp/ isol.
starp.)
OUT
*
*
ON
LED
BO
128 52
1
GI
1278
Sensitve E/F detection Undef. Direction
(SensEF undefDir)
Sensitive Earth
Flt.(comp/ isol.
starp.)
OUT
*
*
ON
LED
BO
151 178 1
GI
1281
Sensitve E/F detection TRIP command
(SensEF TRIP)
Sensitive Earth
Flt.(comp/ isol.
starp.)
OUT
*
ON
ON
LED
BO
151 181 2
GI
1291
Sensitve E/F detection 3U0> pickup
(SensEF 3U0>)
Sensitive Earth
Flt.(comp/ isol.
starp.)
OUT
*
*
LED
BO
1305
>Earth Fault O/C Block 3I0>>> (>EF BLK
3I0>>>)
Earth fault over-
current
SP
ON
OFF
*
LED BI
BO
166 5
1
GI
1307
>Earth Fault O/C Block 3I0>> (>EF
BLOCK 3I0>>)
Earth fault over-
current
SP
ON
OFF
*
LED BI
BO
166 7
1
GI
1308
>Earth Fault O/C Block 3I0> (>EF BLOCK
3I0>)
Earth fault over-
current
SP
ON
OFF
*
LED BI
BO
166 8
1
GI
1309
>Earth Fault O/C Block 3I0p (>EF BLOCK
3I0p)
Earth fault over-
current
SP
ON
OFF
*
LED BI
BO
166 9
1
GI
1310
>Earth Fault O/C Instantaneous trip (>EF
InstTRIP)
Earth fault over-
current
SP
ON
OFF
ON
OFF
LED BI
BO
166 10
1
GI
F.No.
Description
Function
Type of
Informa-
tion
Log-Buffers
Configurable in Matrix
IEC 60870-5-103
E
v
e
n
t
Log
O
n
/O
ff
T
rip
(F
au
lt)
L
o
g
On
/Of
f
G
ro
u
n
d
Fa
ul
t
Log
O
n
/O
ff
Mar
k
ed
in
Osc
ill.
Reco
rd
LE
D
Bin
a
ry
In
p
u
t
Fu
nc
ti
o
n
K
e
y
Bin
a
ry
Ou
tp
u
t
C
h
a
tte
r
B
loc
k
in
g
Ty
pe
In
fo
rm
at
io
n
-No
Da
ta
Un
it
(A
SDU)
G
e
ne
ra
l
In
te
rro
ga
ti
o
n
Содержание siprotec 7SA6
Страница 2: ...Siemens Aktiengesellschaft Book No C53000 G1176 C156 2 ...
Страница 18: ...xviii 7SA6 Manual C53000 G1176 C156 2 ...
Страница 32: ...Introduction 1 14 7SA6 Manual C53000 G1176 C156 2 ...
Страница 82: ...Hardware and Connections 2 50 7SA6 Manual C53000 G1176 C156 2 ...
Страница 119: ...SIPROTEC 4 Devices 4 25 7SA6 Manual C53000 G1176 C156 2 Figure 4 20 CFC Logic example ...
Страница 190: ...Configuration 5 62 7SA6 Manual C53000 G1176 C156 2 ...
Страница 559: ...Control During Operation 7 45 7SA6 Manual C53000 G1176 C156 2 Figure 7 45 Circuit breaker trip test in DIGSI 4 ...
Страница 652: ...Installation and Commissioning 8 78 7SA6 Manual C53000 G1176 C156 2 ...
Страница 724: ...Technical Data 10 56 7SA6 Manual C53000 G1176 C156 ...
Страница 800: ...Appendix A 76 7SA6 Manual C53000 G1176 C156 2 ...
Страница 866: ...Appendix B 66 7SA6 Manual C53000 G1176 C156 2 ...