80070301-2c01ffff
Sensor [SensorElementName] has transitioned to non-recoverable from a less severe state.
Explanation:
The ML2 card has reported a non-recoverable Over temperature condition.
May also be shown as 800703012c01ffff or 0x800703012c01ffff
Severity:
Error
Alert Category:
Critical - Temperature
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0522
SNMP Trap ID:
0
Automatically notify Support:
No
User response:
Complete the following steps until the problem is solved:
1.
Check the IMM event log for any fan or cooling related issues.
2.
Make sure that the room temperature is within operating specifications.
3.
Make sure that the airflow at the front and rear of the server is not obstructed and that fillers are in place and
correctly installed.
4.
Make sure that all baffles included with the system are installed.
5.
Check the heatsink on the ML2 card to ensure that it is free of particulates and dust which would reduce cooling
efficiency.
6.
Remove the heatsink on the ML2 card, check to make sure there is good contact between the heatsink and chip,
and then reinstall the heatsink.
Related Links:
v
“Server features and specifications” on page 7
v
“Removing an ML2 (Ethernet) adapter” on page 254
v
“Thermal grease” on page 282
8007030d-2582ffff
Sensor [SensorElementName] has transitioned to non-recoverable from a less severe state.
Explanation:
This message is for the use case when an implementation has detected a Sensor transitioned to
non-recoverable from less severe.
May also be shown as 8007030d2582ffff or 0x8007030d2582ffff
Severity:
Error
Alert Category:
Critical - Other
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0524
SNMP Trap ID:
50
Automatically notify Support:
No
User response:
RAID Vol State :
80070301-2c01ffff • 8007030d-2582ffff
598
System x3850 X6 and x3950 X6 Types 3837 and 3839: Installation and Service Guide
Содержание X3850 X6
Страница 1: ...System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 2: ......
Страница 3: ...System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 138: ...120 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 225: ...25 26 27 Chapter 5 Parts listing System x3850 X6 and x3950 X6 Types 3837 and 3839 207...
Страница 1682: ...1664 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 1706: ...1688 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 1710: ...1692 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 1728: ...1710 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 1729: ......
Страница 1730: ...Part Number 00FH434 Printed in USA 1P P N 00FH434...