80070201-0304ffff
Sensor [SensorElementName] has transitioned to critical from a less severe state.
Explanation:
IMM has detected Compute Book 4 has warmed to a critical temperature.
May also be shown as 800702010304ffff or 0x800702010304ffff
Severity:
Error
Alert Category:
Critical - Temperature
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0522
SNMP Trap ID:
0
Automatically notify Support:
No
User response:
1.
Check the IMM event log for any fan or cooling related issues.
2.
Make sure that the airflow at the front and rear of the server is not obstructed and that fillers are in place and
correctly installed.
3.
Make sure that the room temperature is within operating specifications.
Related Links:
v
“Server features and specifications” on page 7
80070204-1381ffff
Sensor [SensorElementName] has transitioned to critical from a less severe state.
Explanation:
Power Supply has detected a power supply fan fault.
May also be shown as 800702041381ffff or 0x800702041381ffff
Severity:
Error
Alert Category:
Critical - Fan Failure
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0522
SNMP Trap ID:
11
Automatically notify Support:
No
User response:
Check the IMM event log for which Power Supply had the fault
80070208-1381ffff
Sensor [SensorElementName] has transitioned to critical from a less severe state.
Explanation:
Power Supply has detected a critical PS Therm fault or PS Invalid CFG fault.
May also be shown as 800702081381ffff or 0x800702081381ffff
Severity:
Error
Alert Category:
Critical - Power
Serviceable:
yes
CIM Information: Prefix:
PLAT and
ID:
0522
SNMP Trap ID:
4
Automatically notify Support:
no
User response:
For a PS Therm fault
1.
Check for Power Supply with PS fault in the IMM event log
2.
Replace the Power Supply that has the PS Fault
PS Invalid CFG
80070201-0304ffff • 80070208-1381ffff
Appendix B. Integrated management module II (IMM2) error messages
587
Содержание X3850 X6
Страница 1: ...System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 2: ......
Страница 3: ...System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 138: ...120 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 225: ...25 26 27 Chapter 5 Parts listing System x3850 X6 and x3950 X6 Types 3837 and 3839 207...
Страница 1682: ...1664 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 1706: ...1688 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 1710: ...1692 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 1728: ...1710 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 1729: ......
Страница 1730: ...Part Number 00FH434 Printed in USA 1P P N 00FH434...