5.
(Trained service technician only) Make sure that the microprocessor 3 heat sink is installed correctly and the
thermal material is correctly applied.
6.
(Trained service technician only) Replace microprocessor 3.
Related Links:
v
“Server features and specifications” on page 7
v
“Removing a DDR3 compute book” on page 283
v
“Replacing a DDR3 compute book” on page 284
v
“Removing the DDR3 compute book cover” on page 218
v
“Replacing the DDR3 compute book cover” on page 220
v
“Removing a microprocessor and heat sink” on page 275
v
“Replacing a microprocessor and heat sink” on page 278
v
“Thermal grease” on page 282
806f0107-0304ffff
An Over-Temperature Condition has been detected on [ProcessorElementName].
Explanation:
The microprocessor 4 temperature has risen above the critical level, causing a hard shutdown of the
node.
May also be shown as 806f01070304ffff or 0x806f01070304ffff
Severity:
Error
Alert Category:
Critical - Temperature
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0036
SNMP Trap ID:
0
Automatically notify Support:
No
User response:
Complete the following steps:
1.
Check the IMM event log for any fan or cooling related issues.
2.
Make sure that the airflow at the front and rear of the server is not obstructed and that fillers are in place and
correctly installed.
3.
Make sure that the room temperature is within operating specifications.
4.
Make sure that the microprocessor 4 heat sink is securely installed.
5.
(Trained service technician only) Make sure that the microprocessor 4 heat sink is installed correctly and the
thermal material is correctly applied.
6.
(Trained service technician only) Replace microprocessor 4.
Related Links:
v
“Server features and specifications” on page 7
v
“Removing a DDR3 compute book” on page 283
v
“Replacing a DDR3 compute book” on page 284
v
“Removing the DDR3 compute book cover” on page 218
v
“Replacing the DDR3 compute book cover” on page 220
v
“Removing a microprocessor and heat sink” on page 275
v
“Replacing a microprocessor and heat sink” on page 278
v
“Thermal grease” on page 282
806f0107-0304ffff
Appendix B. Integrated management module II (IMM2) error messages
643
Содержание X3850 X6
Страница 1: ...System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 2: ......
Страница 3: ...System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 138: ...120 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 225: ...25 26 27 Chapter 5 Parts listing System x3850 X6 and x3950 X6 Types 3837 and 3839 207...
Страница 1682: ...1664 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 1706: ...1688 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 1710: ...1692 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 1728: ...1710 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 1729: ......
Страница 1730: ...Part Number 00FH434 Printed in USA 1P P N 00FH434...