8007010d-2b840018
Sensor [SensorElementName] has transitioned from normal to non-critical state.
Explanation:
The eXFlash IPMI Proxy Service has indicated eXFlash DIMM 24 in Compute Book 4 has less than 1%
write warranty remaining
May also be shown as 8007010d2b840018 or 0x8007010d2b840018
Severity:
Warning
Alert Category:
Warning - Other
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0520
SNMP Trap ID:
60
Automatically notify Support:
No
User response:
Information only; warranty is about to expire but no action is required.
Related Links:
v
“Flash DIMMs” on page 51
8007010d-2b84ffff
Sensor [SensorElementName] has transitioned from normal to non-critical state.
Explanation:
The eXFlash IPMI Proxy Service has indicated Compute Book 4 contains an eXFlash DIMM with less
than 1% write warranty remaining
May also be shown as 8007010d2b84ffff or 0x8007010d2b84ffff
Severity:
Warning
Alert Category:
Warning - Other
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0520
SNMP Trap ID:
60
Automatically notify Support:
No
User response:
Information only; warranty is about to expire but no action is required.
Related Links:
v
“Flash DIMMs” on page 51
8007010f-2201ffff
Sensor [SensorElementName] has transitioned from normal to non-critical state.
Explanation:
The GPT (GUID Partition Table) in the disk LUN (Logical Unit Number) is corrupt and may make the
data in the LUN inaccessible to the system and prevent boot.
May also be shown as 8007010f2201ffff or 0x8007010f2201ffff
Severity:
Warning
Alert Category:
Warning - Other
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0520
SNMP Trap ID:
60
Automatically notify Support:
No
User response:
Complete the following steps:
1.
Check the IBM support site for service bulletins or firmware updates that apply to this GPT error.
2.
Set the UEFI setting "DISK GPT Recovery" to "Automatic".
3.
Replace the corrupt disk.
8007010d-2b840018 • 8007010f-2201ffff
584
System x3850 X6 and x3950 X6 Types 3837 and 3839: Installation and Service Guide
Содержание X3850 X6
Страница 1: ...System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 2: ......
Страница 3: ...System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 138: ...120 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 225: ...25 26 27 Chapter 5 Parts listing System x3850 X6 and x3950 X6 Types 3837 and 3839 207...
Страница 1682: ...1664 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 1706: ...1688 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 1710: ...1692 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 1728: ...1710 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 1729: ......
Страница 1730: ...Part Number 00FH434 Printed in USA 1P P N 00FH434...