CIM Information
Provides the prefix of the message ID and the sequence number that is
used by the CIM message registry.
SNMP Trap ID
The SNMP trap ID that is found in the SNMP alert management
information base (MIB).
Automatically contact Service
If this field is set to
Yes
, and you have enabled Electronic Service Agent
™
(ESA), IBM Support will be notified automatically if the event is generated.
While you wait for IBM Support to call, you can perform the
recommended actions for the event.
User response
Indicates what actions you should perform to solve the event.
Perform the steps listed in this section in the order shown until the
problem is solved. After you perform all of the actions that are described
in this field, if you cannot solve the problem, contact IBM Support.
Note:
This list includes error codes and messages that might not apply to
this machine type and model.
The list of IMM2 error messages and suggested actions to correct the detected
server problems are included in this documentation. For more information about
IMM2, see the
Integrated Management Module II User's Guide
at
http://www.ibm.com/support/entry/portal/docdisplay?lndocid=MIGR-5086346.
IMM Events that automatically notify Support
You can configure the Integrated Management Module II (IMM2) to automatically
notify Support (also known as
call home
) if certain types of errors are encountered.
If you have configured this function, see the table for a list of events that
automatically notify Support.
Table 65. Events that automatically notify Support
Event ID
Message String
Automatically
Notify
Support
40000086-00000000
Test Call Home Generated by user [arg1].
Yes
40000087-00000000
Manual Call Home by user [arg1]: [arg2].
Yes
80010202-0701ffff
Numeric sensor
[NumericSensorElementName] going low
(lower critical) has asserted.
Yes
80010202-2801ffff
Numeric sensor SysBrd VBAT going low
(lower critical) has asserted.
Yes
80010902-0701ffff
Numeric sensor
[NumericSensorElementName] going high
(upper critical) has asserted.
Yes
8005010d-2b810001
[SensorElementName] is asserting
predictive failure.
Yes
8005010d-2b810002
[SensorElementName] is asserting
predictive failure.
Yes
438
System x3850 X6 and x3950 X6 Types 3837 and 3839: Installation and Service Guide
Содержание X3850 X6
Страница 1: ...System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 2: ......
Страница 3: ...System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 138: ...120 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 225: ...25 26 27 Chapter 5 Parts listing System x3850 X6 and x3950 X6 Types 3837 and 3839 207...
Страница 1682: ...1664 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 1706: ...1688 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 1710: ...1692 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 1728: ...1710 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 1729: ......
Страница 1730: ...Part Number 00FH434 Printed in USA 1P P N 00FH434...