Follow the general rule for connecting the SAS signal cables to the adapter and
drive backplane: port 0 on the adapter to port 0 on the drive backplane and port
1 on the adapter to port 1 on the drive backplane (depending on the type of
drive backplane you install in the server).
To install the adapter, complete the following steps:
Procedure
1.
Read the safety information and installation guidelines, see “Safety” on page
vii and “Installation guidelines” on page 45.
2.
Turn off the server (see “Turning off the server” on page 41) and all attached
peripheral devices. Disconnect all power cords; then, disconnect all external
cables from the server.
3.
Remove the storage book from the server (see “Removing the storage book”
on page 266).
4.
Open the PCIe retention lever and remove the expansion slot cover from the
slot where you want to install the adapter.
5.
Touch the static-protective package that contains the adapter to any unpainted
surface on the outside of the server; then, grasp the adapter by the top edge
or upper corners of the adapter and remove it from the package.
6.
Align the adapter so that the keys align correctly with the connector on the
storage book board
7.
Insert the adapter into the connector, aligning the edge connector on the
adapter with the connector on the storage book board. Press the edge of the
connector on the adapter
firmly
into the connector. Make sure that the adapter
snaps into the connector on the storage book board securely.
Attention:
Make sure that the adapter is correctly seated into the connector
before you turn on the server. An incorrectly seated adapter might cause
damage to the storage book board or the adapter.
8.
Connect any cables to the adapter, if applicable.
Note:
Follow the general rule for connecting the SAS signal cables to the
adapter and drive backplane: port 0 on the adapter to port 0 on the drive
backplane and port 1 on the adapter to port 1 on the drive backplane
(depending on the type of drive backplanes you installed in the server).
9.
Close the PCIe retention lever.
10.
Reinstall the Storage book.
11.
Perform any configuration tasks that are required for the adapter.
Results
If you have other devices to install or remove, do so now. Otherwise, go to
“Completing the installation” on page 119.
98
System x3850 X6 and x3950 X6 Types 3837 and 3839: Installation and Service Guide
Содержание X3850 X6
Страница 1: ...System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 2: ......
Страница 3: ...System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 138: ...120 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 225: ...25 26 27 Chapter 5 Parts listing System x3850 X6 and x3950 X6 Types 3837 and 3839 207...
Страница 1682: ...1664 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 1706: ...1688 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 1710: ...1692 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 1728: ...1710 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 1729: ......
Страница 1730: ...Part Number 00FH434 Printed in USA 1P P N 00FH434...