W.381800D
[W.381800D]
Explanation:
TPM physical presence is in asserted state TPM physical presence is in asserted state
Severity:
Warning
User response:
Complete the following steps:
1.
Complete any administrative tasks requiring the TPM physical presence switch to be in the "ON" position..
2.
Restore the physical presence switch to the "OFF" position and reboot the system.
3.
Replace the standard I/O book.
W.3868001
[W.3868001]
Explanation:
BOFM: Reset loop avoided - Multiple resets not allowed. BOFM: Reset loop avoided - Multiple resets
not allowed
Severity:
Warning
User response:
Complete the following steps:
1.
Update all firmware (including adapter firmware) to the latest levels.
2.
If problem persists escalate to the next level of support.
W.3868002
[W.3868002]
Explanation:
BOFM: Error communicating with the IMM - BOFM may not be deployed correctly. BOFM: Error
communicating with the IMM - BOFM may not be deployed correctly
Severity:
Error
User response:
Complete the following steps:
1.
Update all firmware (including adapter firmware) to the latest levels.
2.
If problem persists escalate to the next level of support.
W.3938002
[W.3938002]
Explanation:
A boot configuration error has been detected. Boot Configuration Error
Severity:
Warning
User response:
Complete the following steps:
1.
F1 Setup -> Save Settings
2.
Retry OOB config update
W.50001
[W.50001]
Explanation:
A DIMM has been disabled due to an error detected during POST. DIMM Disabled
Severity:
Info
User response:
Complete the following steps:
1.
If the DIMM was disabled because of a memory fault, follow the procedure for that event.
2.
If no memory fault is recorded in the logs and no DIMM connector error LEDs are lit, re-enable the DIMM
through the Setup utility or the Advanced Settings Utility (ASU).
3.
If problem persists, Power cycle the node from management console.
4.
Reset IMM to default settings.
5.
Reset UEFI to default settings.
6.
Reflash IMM and UEFI firmware.
7.
Swap the DIMM from the disabled slot with a matching DIMM. If the slot remains disabled, replace the compute
book.
W.381800D • W.50001
1684
System x3850 X6 and x3950 X6 Types 3837 and 3839: Installation and Service Guide
Содержание X3850 X6
Страница 1: ...System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 2: ......
Страница 3: ...System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 138: ...120 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 225: ...25 26 27 Chapter 5 Parts listing System x3850 X6 and x3950 X6 Types 3837 and 3839 207...
Страница 1682: ...1664 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 1706: ...1688 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 1710: ...1692 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 1728: ...1710 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 1729: ......
Страница 1730: ...Part Number 00FH434 Printed in USA 1P P N 00FH434...