806f060d-0408ffff
Array [ComputerSystemElementName] has failed.
Explanation:
Drive 8 is part of an RAID array that is in the failed condition. To identify drives in the failed array all
member drives will report this message.
May also be shown as 806f060d0408ffff or 0x806f060d0408ffff
Severity:
Error
Alert Category:
Critical - Hard Disk drive
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0176
SNMP Trap ID:
5
Automatically notify Support:
Yes
User response:
v
Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
v
Replace the hard disk drives that are indicated by a lit status LED.
v
Recreate the array.
v
Restore data from backup.
Related Links:
v
“Removing 2.5-inch and 1.8-inch hot-swap drives” on page 231
v
“Replacing 2.5-inch and 1.8-inch hot-swap drives” on page 232
806f060d-0409ffff
Array [ComputerSystemElementName] has failed.
Explanation:
Drive 9 is part of an RAID array that is in the failed condition. To identify drives in the failed array all
member drives will report this message.
May also be shown as 806f060d0409ffff or 0x806f060d0409ffff
Severity:
Error
Alert Category:
Critical - Hard Disk drive
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0176
SNMP Trap ID:
5
Automatically notify Support:
Yes
User response:
v
Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
v
Replace the hard disk drives that are indicated by a lit status LED.
v
Recreate the array.
v
Restore data from backup.
Related Links:
v
“Removing 2.5-inch and 1.8-inch hot-swap drives” on page 231
v
“Replacing 2.5-inch and 1.8-inch hot-swap drives” on page 232
806f060d-0408ffff • 806f060d-0409ffff
Appendix B. Integrated management module II (IMM2) error messages
1029
Содержание X3850 X6
Страница 1: ...System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 2: ......
Страница 3: ...System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 138: ...120 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 225: ...25 26 27 Chapter 5 Parts listing System x3850 X6 and x3950 X6 Types 3837 and 3839 207...
Страница 1682: ...1664 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 1706: ...1688 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 1710: ...1692 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 1728: ...1710 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 1729: ......
Страница 1730: ...Part Number 00FH434 Printed in USA 1P P N 00FH434...