Reliability, availability, and serviceability
This topic provides an overview of the server reliability, availability, and
serviceability (RAS) features.
Three important computer design features are reliability, availability, and
serviceability (RAS). The RAS features help to ensure the integrity of the data that
is stored in the server, the availability of the server when you need it, and the ease
with which you can diagnose and correct problems.
Your server has the following RAS features:
v
3-year parts and 3-year labor limited warranty (Machine Type 3837) or 4-year
parts and 4-year labor limited warranty (Machine Type 3839)
v
24-hour support center
v
Automatic error retry and recovery
v
Automatic restart on nonmaskable interrupt (NMI)
v
Automatic restart after a power failure
v
Backup basic input/output system switching under the control of the integrated
management module (IMM)
v
Built-in monitoring for fan, power, temperature, voltage, and power-supply
redundancy
v
Cable-presence detection on most connectors
v
Chipkill memory protection
v
Corrected machine check interrupt (CMCI)
v
Single-device data correction (SDDC) for x4 DRAM technology DIMMs
(available on 16 GB DIMMs only). Ensures that data is available on a single x4
DRAM DIMM after a hard failure of up to two DRAM DIMMs. One x4 DRAM
DIMM in each rank is reserved as a space device.
v
Diagnostic support for ServeRAID and Ethernet adapters
v
DRAM single device data correction (SDDC)
v
Dynamic memory migration
v
Enhanced DRAM single device data correction (SDDC+1)
v
Enhanced DRAM double device data correction (SDDC+1)
v
Error codes and messages
v
Error correcting code (ECC) L3 cache and system memory
v
Failed DIMM identification
v
Full Array Memory Mirroring (FAMM) redundancy
v
Hot-swap cooling fans with speed-sensing capability
v
Hot-swap hard disk drives
v
Hot-swap and redundant power supplies
v
Integrated baseboard management controller (BMC) subsystem
v
Integrated management module (IMM)
v
LCD system information display panel
v
Light path LEDs for DIMMs, microprocessors, PCIe adapters, hard disk drives,
solid state drives, power supplies, fans, PCIe modules, and I/O modules
v
Memory address parity protection
v
Memory demand and patrol scrubbing
v
Memory error correcting code and parity test
v
Memory downsizing (non-mirrored memory). After a restart of the server after
the memory controller detects a non-mirrored uncorrectable error and the
memory controller cannot recover operationally, the IMM logs the uncorrectable
error and informs POST. POST logically maps out the memory with the
uncorrectable error, and the server restarts with the remaining installed memory.
v
Memory mirroring and memory rank sparing support
v
Memory thermal throttling
18
System x3850 X6 and x3950 X6 Types 3837 and 3839: Installation and Service Guide
Содержание X3850 X6
Страница 1: ...System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 2: ......
Страница 3: ...System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 138: ...120 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 225: ...25 26 27 Chapter 5 Parts listing System x3850 X6 and x3950 X6 Types 3837 and 3839 207...
Страница 1682: ...1664 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 1706: ...1688 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 1710: ...1692 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 1728: ...1710 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 1729: ......
Страница 1730: ...Part Number 00FH434 Printed in USA 1P P N 00FH434...