Explanation:
An uncorrectable memory error was detected in DIMM slot % on rank %. An uncorrectable memory
error was detected on processor % channel %. The failing DIMM within the channel could not be determined. An
uncorrectable memory error has been detected. Fatal Memory Error Occurred
Severity:
Error
User response:
Complete the following steps:
1.
If the node has recently been installed, moved, serviced, or upgraded, verify that the DIMM is properly seated
and visually verify that there is no foreign material in any DIMM connector on that memory channel. If either of
these conditions is found, correct and retry with the same DIMM. (Note: Event Log may contain a recent 00580A4
event denoting detected change in DIMM population that could be related to this problem.)
2.
Check IBM support site for an applicable service bulletin or firmware update that applies to this memory error.
3.
If no problem is observed on the DIMM connectors or the problem persists, replace the DIMM identified by
LightPath and/or event log entry. If this is a flash DIMM, make sure it is still under warranty before replacing it.
4.
If problem re-occurs on the same DIMM connector, replace the other DIMMs on the same memory channel. If
this is a flash DIMM, make sure it is still under warranty before replacing it
5.
Replace compute book.
6.
(Trained Service technician only) Replace affected Processor.
S.51006
[S.51006]
Explanation:
A memory mismatch has been detected. Please verify that the memory configuration is valid. One or
More Mismatched DIMMs Detected
Severity:
Error
User response:
Complete the following steps:
1.
Could follow an uncorrectable memory error or failed memory test. Check log and service that event first.
DIMMs disabled by other errors or actions could cause this event.
2.
Verify that the DIMMs are installed in the correct population sequence, according to the service information for
this product.
3.
Disable memory mirroring and sparing. If this action eliminates the mismatch, check IBM Support site for
information related to this problem.
4.
Reflash UEFI firmware.
5.
Replace DIMM. If this is a flash DIMM, make sure it is still under warranty before replacing it.
6.
(Trained Service technician only) Replace Processor.
S.51009
[S.51009]
Explanation:
No system memory has been detected. No Memory Detected
Severity:
Error
User response:
Complete the following steps:
1.
Make sure that one or more DIMMs are installed in the server, and resolve any other currently existing memory
errors.
2.
If no memory fault is recorded in the logs and no DIMM connector error LEDs are lit, verify that all DIMM
connectors are enabled using the Setup utility or the Advanced Settings Utility (ASU).
3.
Re-Install all DIMMs verifying the correct population sequence, according to the service information for this
product.
4.
(Trained service technician only) Replace the processor.
5.
Replace the compute book.
S.51003 • S.51009
1678
System x3850 X6 and x3950 X6 Types 3837 and 3839: Installation and Service Guide
Содержание X3850 X6
Страница 1: ...System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 2: ......
Страница 3: ...System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 138: ...120 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 225: ...25 26 27 Chapter 5 Parts listing System x3850 X6 and x3950 X6 Types 3837 and 3839 207...
Страница 1682: ...1664 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 1706: ...1688 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 1710: ...1692 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 1728: ...1710 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 1729: ......
Страница 1730: ...Part Number 00FH434 Printed in USA 1P P N 00FH434...