806f050d-0402ffff
Array [ComputerSystemElementName] is in critical condition.
Explanation:
Drive 2 is part of an RAID array that is in critical condition. Immediate action is required to avoid a
system outage. To identify drives in the critical array all member drives will report this message.
May also be shown as 806f050d0402ffff or 0x806f050d0402ffff
Severity:
Error
Alert Category:
Critical - Hard Disk drive
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0174
SNMP Trap ID:
5
Automatically notify Support:
No
User response:
v
Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
v
Replace the hard disk drive that is indicated by a lit status LED.
Related Links:
v
“Removing 2.5-inch and 1.8-inch hot-swap drives” on page 231
v
“Replacing 2.5-inch and 1.8-inch hot-swap drives” on page 232
806f050d-0403ffff
Array [ComputerSystemElementName] is in critical condition.
Explanation:
Drive 3 is part of an RAID array that is in critical condition. Immediate action is required to avoid a
system outage. To identify drives in the critical array all member drives will report this message.
May also be shown as 806f050d0403ffff or 0x806f050d0403ffff
Severity:
Error
Alert Category:
Critical - Hard Disk drive
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0174
SNMP Trap ID:
5
Automatically notify Support:
No
User response:
v
Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
v
Replace the hard disk drive that is indicated by a lit status LED.
Related Links:
v
“Removing 2.5-inch and 1.8-inch hot-swap drives” on page 231
v
“Replacing 2.5-inch and 1.8-inch hot-swap drives” on page 232
806f050d-0402ffff • 806f050d-0403ffff
Appendix B. Integrated management module II (IMM2) error messages
1015
Содержание X3850 X6
Страница 1: ...System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 2: ......
Страница 3: ...System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 138: ...120 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 225: ...25 26 27 Chapter 5 Parts listing System x3850 X6 and x3950 X6 Types 3837 and 3839 207...
Страница 1682: ...1664 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 1706: ...1688 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 1710: ...1692 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 1728: ...1710 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 1729: ......
Страница 1730: ...Part Number 00FH434 Printed in USA 1P P N 00FH434...