409-904-000
Nvidia::DiagnosticServiceProvider::Query Test Failed
Explanation:
Nvidia GPU Query Test Failed.
Severity:
Error
Serviceable:
Yes
Recoverable:
No
Automatically notify Support:
No
User response:
Complete the following steps:
1.
Verify that the GPU is seated in the PCIe slot correctly by reseating the GPU. Then power cycle the system.
2.
Verify that the power connectors to the GPU are connected firmly. Then power cycle the system.
3.
Run nvidia-smi -q In some cases this will report a poorly connected power cable.
4.
Rerun the diagnostics, using the same GPU, on system that is known to be working. A variety of system issues
can cause diagnostic failure.
5.
If the problem remains, contact your IBM technical-support representative.
Related Links:
v
IBM Support Website
v
Latest level of DSA
v
Latest level of BMC/IMM
409-905-000
Nvidia::DiagnosticServiceProvider::Matrix Test Failed
Explanation:
Nvidia GPU Matrix Test Failed.
Severity:
Error
Serviceable:
Yes
Recoverable:
No
Automatically notify Support:
No
User response:
Complete the following steps:
1.
Verify that the GPU is seated in the PCIe slot correctly by reseating the GPU. Then power cycle the system.
2.
Verify that the power connectors to the GPU are connected firmly. Then power cycle the system.
3.
Run nvidia-smi -q In some cases this will report a poorly connected power cable.
4.
Rerun the diagnostics, using the same GPU, on system that is known to be working. A variety of system issues
can cause diagnostic failure.
5.
If the problem remains, contact your IBM technical-support representative.
Related Links:
v
IBM Support Website
v
Latest level of DSA
v
Latest level of BMC/IMM
409-904-000 • 409-905-000
416
System x3850 X6 and x3950 X6 Types 3837 and 3839: Installation and Service Guide
Содержание X3850 X6
Страница 1: ...System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 2: ......
Страница 3: ...System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 138: ...120 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 225: ...25 26 27 Chapter 5 Parts listing System x3850 X6 and x3950 X6 Types 3837 and 3839 207...
Страница 1682: ...1664 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 1706: ...1688 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 1710: ...1692 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 1728: ...1710 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 1729: ......
Страница 1730: ...Part Number 00FH434 Printed in USA 1P P N 00FH434...