Statement 34:
CAUTION:
To reduce the risk of electric shock or energy hazards:
• This equipment must be installed by trained service personnel in a
restricted-access location, as defined by the NEC and IEC 60950-1,
First Edition, The Standard for Safety of Information
Technology Equipment.
• Connect the equipment to a properly grounded safety extra low
voltage (SELV) source. A SELV source is a secondary circuit that
is designed so that normal and single fault conditions do not
cause the voltages to exceed a safe level (60 V direct current).
• Incorporate a readily available approved and rated disconnect
device in the field wiring.
• See the specifications in the product documentation for the
required circuit-breaker rating for branch circuit
overcurrent protection.
• Use copper wire conductors only. See the specifications in the
product documentation for the required wire size.
• See the specifications in the product documentation for the
required torque values for the wiring-terminal screws.
>240VA
Statement 35:
CAUTION:
Hazardous energy present. Voltages with hazardous energy
might cause heating when shorted with metal, which might
result in splattered metal, burns, or both.
The 8U version of the server is intended for use in a system/rack always installed
on the load side of a Power Distribution Unit (PDU) or Uninterruptible Power
Supply (UPS) supplying a maximum 20 A branch circuit protection. The overall
system/rack connection to mains power is to be a Pluggable Type B connector.
This server is suitable for use on an IT power-distribution system whose maximum
phase-to-phase voltage is 240 V under any distribution fault condition.
Important:
Maschinenlärminformations-Verordnung - 3. GPSGV, der höchste
Schalldruckpegel beträgt 70 dB(A) oder weniger.
The product is not suitable for use at visual display workplaces according to §2 of
the German Ordinance for Work with Visual Display Units. Das Produkt ist nicht
für den Einsatz an Bildschirmarbeitsplätzen im Sinne § 2 der
Bildschirmarbeitsverordnung geeignet.
xiv
System x3850 X6 and x3950 X6 Types 3837 and 3839: Installation and Service Guide
Содержание X3850 X6
Страница 1: ...System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 2: ......
Страница 3: ...System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 138: ...120 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 225: ...25 26 27 Chapter 5 Parts listing System x3850 X6 and x3950 X6 Types 3837 and 3839 207...
Страница 1682: ...1664 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 1706: ...1688 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 1710: ...1692 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 1728: ...1710 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 1729: ......
Страница 1730: ...Part Number 00FH434 Printed in USA 1P P N 00FH434...