Note:
The optional dual-port and quad-port Ethernet adapters with iSCSI,
vNIC, TCP/IP Offload Engine (TOE), Fiber Channel over Ethernet (FCoE),
and Wake on LAN support, can provide up to 10 Gb capability.
Video controller (integrated into the IMM2):
v
Matrox G200eR core (two analog ports: one front and one rear that can
be connected at the same time)
Note:
The maximum video resolution is 1600 x 1200 at 75 Hz (UXGA),
with support for 1680 x 1050 (WSXGA+) wide screen resolution.
– DDR3 528 MHz SDRAM video memory controller
– Avocent Digital Video Compression
– Video memory is not expandable
Size:
v
Height (4-socket): 172.8 mm (6.8 inches)
v
Height (8-socket): 350.6 mm (13.8 inches
v
Depth (4-socket and 8-socket): 811.2 mm (31.9 inches)
v
Width (4-socket and 8-socket): 447 mm (17.5 inches)
v
Maximum weight (4-socket): 54.7 kg (120.3 lbs) when fully configured
v
Maximum weight (8-socket): 110 kg (242.5 lbs) when fully configures
Acoustical noise emissions:
4-socket system:
v
Declared sound power, idling: 6.3 bels
v
Declared sound power, operating: 6.7 bels
8-socket system:
v
Declared sound power, idling: 6.6 bels
v
Declared sound power, operating: 7.0 bels
Environment:
Note:
When eXFlash DIMMs are installed in the server, the Flash DIMMs
supported environment is:
Temperature: 5°C to 30°C (41°F to 86°F)
Altitude: 0 to 1000 m (3,281 ft)
v
Air temperature:
– Server on: 5°C to 40°C (41°F to 104°F); altitude: 0 to 3050 m (10,000 ft)
derate maximum dry bulb temperature by 1°C (1.8°F) per 175 m (574
ft) above 950 m (3,117 ft). Maximum rate of change 20°C (68°F) per
hour.
– Server off: 5°C to 45°C (41° to 113`°F)
– Shipment: -40°C to +60°C (-40°F to 140°F)
Note:
The server is designed to the ASHRAE Class A3 guidelines.
v
Humidity range (noncondensing):
– Server on: Minimum = higher (more moisture) of -12°C (10°F) dew
point and 8% to 85% relative humidity; maximum dew point: 24°C
(75°F)
– Server off: 8% to 85% relative humidity; maximum dew point: 27°C
(80°F)
– Shipment: 5% to 100%
v
Particulate contamination
10
System x3850 X6 and x3950 X6 Types 3837 and 3839: Installation and Service Guide
Содержание X3850 X6
Страница 1: ...System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 2: ......
Страница 3: ...System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 138: ...120 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 225: ...25 26 27 Chapter 5 Parts listing System x3850 X6 and x3950 X6 Types 3837 and 3839 207...
Страница 1682: ...1664 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 1706: ...1688 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 1710: ...1692 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 1728: ...1710 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 1729: ......
Страница 1730: ...Part Number 00FH434 Printed in USA 1P P N 00FH434...