I.1800F
[I.1800F]
Explanation:
A processor family mismatch has been detected for one or more processor packages. Processors have
mismatched Family
Severity:
Error
User response:
Complete the following steps:
1.
Verify that matching Processors are installed in the correct Processor sockets according to the service information
for this product
2.
Check IBM support site for an applicable service bulletin or firmware update that applies to this Processor error.
3.
Replace the compute book.
I.18010
[I.18010]
Explanation:
A processor stepping mismatch has been detected for one or more processor packages. Processors of
the same model have mismatched Stepping ID
Severity:
Error
User response:
Complete the following steps:
1.
Verify that matching Processors are installed in the correct Processor sockets according to the service information
for this product.
2.
Check IBM support site for an applicable service bulletin or firmware update that applies to this Processor error.
3.
Replace the compute book.
I.2018002
[I.2018002]
Explanation:
The device found at Bus % Device % Function % could not be configured due to resource constraints.
The Vendor ID for the device is % and the Device ID is %. OUT_OF_RESOURCES (PCI Option ROM)
Severity:
Info
User response:
Complete the following steps:
1.
If this PCIe device and/or any attached cables were recently installed, moved, serviced or upgraded, reseat
adapter and any attached cables.
2.
Check IBM support site for any applicable service bulletin or UEFI or adapter firmware update that applies to
this error. NOTE: It may be necessary to disable unused option ROMs from UEFI F1 setup or ASU or using
adapter manufacturer utilities so that adapter firmware can be updated.
I.2018003
[I.2018003]
Explanation:
A bad option ROM checksum was detected for the device found at Bus % Device % Function %. The
Vendor ID for the device is % and the Device ID is %. ROM CHECKSUM ERROR
Severity:
Error
User response:
Complete the following steps:
1.
If this PCIe device and/or any attached cables were recently installed, moved, serviced or upgraded, reseat
adapter and any attached cables.
2.
Check IBM support site for any applicable service bulletin or UEFI or adapter firmware update that applies to
this error. NOTE: It may be necessary to configure slot to Gen1 or to use special utility software so that adapter
firmware can be upgraded. Gen1/Gen2 settings can be configured via F1 Setup -> System Settings -> Devices and
I/O Ports -> PCIe Gen1/Gen2/Gen3 Speed Selection, or the ASU Utility.
3.
Move adapter to a different system slot, if available.
4.
Replace adapter.
I.1800F • I.2018003
1670
System x3850 X6 and x3950 X6 Types 3837 and 3839: Installation and Service Guide
Содержание X3850 X6
Страница 1: ...System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 2: ......
Страница 3: ...System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 138: ...120 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 225: ...25 26 27 Chapter 5 Parts listing System x3850 X6 and x3950 X6 Types 3837 and 3839 207...
Страница 1682: ...1664 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 1706: ...1688 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 1710: ...1692 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 1728: ...1710 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Страница 1729: ......
Страница 1730: ...Part Number 00FH434 Printed in USA 1P P N 00FH434...