Страница 1: ...IBM IBM Netfinity 4500R Installation Guide SC09 N819 30...

Страница 2: ...ct warranties and notices on page 31 First Edition March 2000 COPYRIGHT INTERNATIONAL BUSINESS MACHINES CORPORATION 2000 All rights reserved Note to U S Government Users Documentation related to restr...

Страница 3: ...24 ServerGuide startup problems 26 Troubleshooting chart 27 Appendix A Product warranties and notices 31 Warranty Statements 31 IBM Statement of Limited Warranty for United States Puerto Rico and Can...

Страница 4: ...IBM Netfinity 4500R Installation Guide...

Страница 5: ...on kirjanen ennen kuin asennat t m n tuotteen Avant de proc der l installation de ce produit lisez le manuel Safety Information Vor Beginn der Installation die Brosch re mit Sicherheitshinweisen lesen...

Страница 6: ...es de instalar este produto leia o folheto Informa es sobre Seguran a Antes de instalar este producto lea la Informaci n de Seguridad L s s kerhetsinformationen innan du installerar den h r produkten...

Страница 7: ...on any equipment when there is evidence of fire water or structural damage Disconnect the attached power cords telecommunications systems networks and modems before you open the device covers unless i...

Страница 8: ...as required by local ordinances or regulations Statement 3 CAUTION When laser products such as CD ROMs DVD drives fiber optic devices or transmitters are installed note the following Do not remove th...

Страница 9: ...ement 5 CAUTION The power control button on the device and the power supply do not turn off the electrical current supplied to the device The device also might have more than one power cord To remove...

Страница 10: ...x IBM Netfinity 4500R Installation Guide Safety...

Страница 11: ...detailed information about your server Your server comes with a three year limited warranty and 90 Day IBM Start Up Support If you have access to the World Wide Web you can obtain up to date informat...

Страница 12: ...d functions Netfinity Advanced System Management processor Dual channel Ultra3 SCSI controller One 10BASE T 100BASE TX AMD Ethernet controller Two serial ports One parallel port Two universal serial b...

Страница 13: ...ces provide important tips guidance or advice Attention These notices indicate possible damage to programs devices or data An attention notice is placed just before the instruction or situation in whi...

Страница 14: ...page 5 The blue color on components and labels identifies touch points where a component can be gripped a latch moved and so on Note The illustrations in this document might differ slightly from your...

Страница 15: ...ng wrist watches Remove items from your shirt pocket such as pens or pencils that could fall into the server as you lean over it Take care to avoid dropping any metallic objects such as paper clips ha...

Страница 16: ...ows the location of the PCI expansion slots on the system board Note The illustrations in this document might differ slightly from your hardware PCI slot 5 64 bit 33 MHz J44 PCI slot 4 64 bit 33 MHz J...

Страница 17: ...ng these devices refer to the following Web site and use a search term of ESD http www ibm com 1 Review the safety precautions listed in Safety on page v 2 Turn off the server Disconnect the signal ca...

Страница 18: ...ers The following illustration shows the rerouting of the SCSI cable if you install an IBM ServeRAID adapter 1 Disconnect the cable from SCSI connector B on the system board 2 Connect the cable to the...

Страница 19: ...lowing illustration to install a hot swap drive Note The illustrations in this document might differ slightly from your hardware To install a drive in a hot swap bay Attention When you handle Electros...

Страница 20: ...processor and the microprocessor installed in U3 is the application processor Attention To avoid damage and ensure proper server operation when you install a new or an additional microprocessor use mi...

Страница 21: ...d or a microprocessor 1 Review the safety precautions listed in Safety on page v 2 Turn off the server Disconnect the signal cables then disconnect the power cords 3 Remove the cover 4 Remove fan 3 5...

Страница 22: ...observe the following precaution Statement 8 CAUTION Never remove the cover on a power supply or any part that has the following label attached Hazardous voltage current and energy levels are present...

Страница 23: ...talled for proper cooling 2 Place the power supply handle in the open position 3 Slide the power supply into the chassis and press the handle to the closed position 4 Plug the power cord into the powe...

Страница 24: ...ion using the Configuration Setup Utility program Refer to the User s Reference on the IBM Netfinity Documentation CD for more information See the following illustration to install additional memory N...

Страница 25: ...connectors on the rear of the server and cable routing for the server Note The illustrations in this document might differ slightly from your hardware Mouse Advanced System Management port C Advanced...

Страница 26: ...16 IBM Netfinity 4500R Installation Guide Cabling the server...

Страница 27: ...system power supply is turned off and AC current is present When this light is off either a power supply AC power or a light has failed Attention If this light is off it does not mean there is no ele...

Страница 28: ...derly shutdown of the operating system if this feature is supported by your operating system and places the server in standby mode Note After turning off the server wait at least 5 seconds before pres...

Страница 29: ...the power supply During normal operation both the AC and DC power lights are on For information about any other combination of lights refer to the User s Reference on the IBM Netfinity Documentation C...

Страница 30: ...is an active connection on the Ethernet port Ethernet transmit receive activity light When this green light is on there is transmit or receive activity to or from the server Information light This amb...

Страница 31: ...ault values resolve configuration conflicts and perform a low level format on a SCSI hard disk drive ServeRAID programs If you have a ServeRAID adapter installed in your server you must use the ServeR...

Страница 32: ...eached and enables you to resolve system problems remotely using a serial or Advanced System Management Interconnect connection even if the server is powered down or the operating system has locked up...

Страница 33: ...p microprocessor If the problem persists call for service One short POST completed successfully One beep also occurs after POST if you enter an incorrect password Two short Follow the instructions tha...

Страница 34: ...tion CD for more information about the POST beep codes Two long and two short POST does not support the optional video adapter Replace the optional video adapter with one that is supported by the serv...

Страница 35: ...verify that the parallel port setting is correct 11xx Serial port error Verify that the serial cable is connected correctly 1162 Serial port configuration conflict Start the Configuration Setup progra...

Страница 36: ...or IRQ assignments Be sure that the hard disk drive is connected properly The Operating System Installation program continuously loops Free up more space on the hard disk ServerGuide won t start your...

Страница 37: ...tart some application programs Verify that 1 The primary monitor cable is connected to the video port 2 You installed the necessary device drivers for the applications If the items above are correct a...

Страница 38: ...the startup microprocessor is seated properly If it is replace the startup microprocessor If the problem remains call for service Memory problems Suggested action The amount of memory displayed is le...

Страница 39: ...t update the configuration If the problem remains call for service Expansion enclosure problems Suggested action The SCSI expansion enclosure used to work but does not work now Verify that 1 The cable...

Страница 40: ...30 IBM Netfinity 4500R Installation Guide Troubleshooting chart...

Страница 41: ...rchase for your use and not for resale from IBM or your reseller The term Machine means an IBM machine its features conversions upgrades elements or accessories or any combination of them The term Mac...

Страница 42: ...ARE LIMITED IN DURATION TO THE WARRANTY PERIOD NO WARRANTIES APPLY AFTER THAT PERIOD Items Not Covered by Warranty IBM does not warrant uninterrupted or error free operation of a Machine Unless specif...

Страница 43: ...seller for any reason You should remove all such information from the Machine prior to its return Production Status Each IBM Machine is manufactured from new parts or new and used parts In some cases...

Страница 44: ...ervice is performed The IBM Warranty for Machines IBM warrants that each Machine 1 is free from defects in materials and workmanship and 2 conforms to IBM s Official Published Specifications The warra...

Страница 45: ...nty service involves the exchange of a Machine or part the item IBM or your reseller replaces becomes its property and the replacement becomes yours You represent that all removed items are genuine an...

Страница 46: ...if recurring 12 months charges apply for the Machine that is the subject of the claim This limit also applies to IBM s suppliers and your reseller It is the maximum for which IBM its suppliers and yo...

Страница 47: ...993 will not apply in respect of any goods which IBM provides if you require the goods for the purposes of a business as defined in that Act Limitation of Liability The following is added to this Sect...

Страница 48: ...as justified by the reduced value of the unrepaired Machine or ask for a cancellation of the respective agreement for such Machine and get your money refunded Extent of Warranty The second paragraph...

Страница 49: ...entire liability to you for actual damages arising in all situations involving nonperformance by IBM in respect of the subject matter of this Statement of Warranty will be limited to the charge paid b...

Страница 50: ...is at your own risk Edition Notice INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS PUBLICATION AS IS WITHOUT WARRANTY OF ANY KIND EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE I...

Страница 51: ...tury This IBM PC product cannot prevent errors that might occur if software you use or exchange data with is not ready for the Year 2000 IBM software that comes with this product is Year 2000 Ready Ho...

Страница 52: ...pacity may vary depending on operating environments Maximum internal hard disk drive capacities assume the replacement of any standard hard disk drives and population of all hard disk drive bays with...

Страница 53: ...ay cause radio interference in which case the user may be required to take adequate measures United Kingdom telecommunications safety requirement Notice to Customers This apparatus is approved under a...

Страница 54: ...d set consisting of a minimum 18 AWG Type SVT or SJT three conductor cord a maximum of 15 feet in length and a parallel blade grounding type attachment plug rated 15 amperes 125 volts For units intend...

Страница 55: ...n Sweden Syria Togo Tunisia Turkey former USSR Vietnam former Yugoslavia Zaire Zimbabwe 13F9997 Denmark 14F0015 Bangladesh Burma Pakistan South Africa Sri Lanka 14F0033 Antigua Bahrain Brunei Channel...

Страница 56: ...46 IBM Netfinity 4500R Installation Guide...

Страница 57: ...r installing 10 specifications 2 N non hot swap drive installing 9 specifications 2 NOS See operating system notices electronic emission Class A 42 FCC Class A 42 miscellaneous 42 product 42 trademark...

Страница 58: ...48 IBM Netfinity 4500R Installation Guide...

Страница 59: ......

Страница 60: ...IBM Part Number 09N8193 Printed in the United States of America on recycled paper containing 10 recovered post consumer fiber SC09 N819 30 07SC09N81930 09N8193 0409N8193...