MB86R02 ‘Jade-D’ Hardware Manual V1.64
15.7.1.4
Demand transfer
Operation
In demand transfer mode, DMA transfer is executed as a one-off transfer when the transfer
request is asserted and the number of transfers is set in the DMACA/TC registers. In this case,
DMACA/BC is set to "0".
In this mode, DMACA/BC values are ignored. DMACA/TC are decremented by 1 after the DMA
transfer has completed. DMA transfer therefore ends after the last transfer (TC is16’h0000) has
been completed.
Transfer gap
After completing 1 transfer, DMAC temporarily negates the bus request to the arbiter even
though the transfer request is asserted. This operation prevents the DMAC from blocking the bus.
This transfer gap can be used to update register settings (e.g. disable/interruption setting) to the
DMAC during DMA transfers.
Transfer request
External (DREQ) and peripheral (IDREQ) requests are permissible in demand transfer mode,
however software requests are prohibited.
•
External request
Set "0" to DMACA/ST, and set 5'b01110 (H level of transfer request) or 5'b01111 (L level of
transfer request) to DMACA/IS
•
Peripheral request
Set "0" to DMACA/ST, and set 5'b1**** (H level of transfer request) to DMACA/IS
When an external request or peripheral request is selected, the DMAC detects the transfer
request level.
Содержание MB86R02
Страница 24: ...MB86R02 Jade D Hardware Manual V1 64 ...
Страница 76: ...3 2 MB86R02 Jade D Hardware Manual V1 64 Figure 3 1 Memory map 1 ...
Страница 77: ...3 3 MB86R02 Jade D Hardware Manual V1 64 Figure 3 2 Memory map 2 ...
Страница 167: ...8 8 MB86R02 Jade D Hardware Manual V1 64 ...
Страница 214: ...11 7 MB86R02 Jade D Hardware Manual V1 64 15 16 cycles initial value ...
Страница 216: ...11 9 MB86R02 Jade D Hardware Manual V1 64 0000011 b 4MB 0111111 b 64MB 0000111 b 8MB 1111111 b 128MB ...
Страница 304: ...16 5 MB86R02 Jade D Hardware Manual V1 64 The flow of a read action is shown below Figure 16 5 Read process flow ...
Страница 497: ...18 139 MB86R02 Jade D Hardware Manual V1 64 VSYNC is output 1 dot clock faster than HSYNC ...
Страница 558: ...18 200 MB86R02 Jade D Hardware Manual V1 64 017 S S S S S S S S Int Frac 060 018 dBdy S S S S S S S S Int Frac ...
Страница 678: ......
Страница 680: ......
Страница 682: ...22 2 MB86R02 Jade D Hardware Manual V1 00 FUJITSU PROPRIETARY AND CONFIDENTIAL ...
Страница 684: ...22 2 MB86R02 Jade D Hardware Manual V1 00 FUJITSU PROPRIETARY AND CONFIDENTIAL Figure 22 14 TCON flow diagram ...
Страница 811: ...29 24 MB86R02 Jade D Hardware Manual V1 64 ...
Страница 852: ...34 13 MB86R02 Jade D Hardware Manual V1 64 3 1LSB VFST VZT 1022 INLn 1LSBxn VZT Vn 1LSB DNLn Vn 1 Vn 1LSB 1 ...
Страница 884: ...34 45 MB86R02 Jade D Hardware Manual V1 64 ...