S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
22-144
Cisco MDS 9000 Family Command Reference
OL-18089-01, Cisco MDS NX-OS Release 4.x
Chapter 22 Show Commands
show flogi
In a Fibre Channel fabric, each host or disk requires an FCID. Use the
show flogi database
command
to verify if a storage device is displayed in the Fabric login (FLOGI) table as in the examples below. If
the required device is displayed in the FLOGI table, the fabric login is successful. Examine the FLOGI
database on a switch that is directly connected to the host HBA and connected ports.
Examples
The following example displays details on the FLOGI database:
switch#
show flogi database
---------------------------------------------------------------------------
INTERFACE VSAN FCID PORT NAME NODE NAME
---------------------------------------------------------------------------
sup-fc0 2 0xb30100 10:00:00:05:30:00:49:63 20:00:00:05:30:00:49:5e
fc9/13 1 0xb200e2 21:00:00:04:cf:27:25:2c 20:00:00:04:cf:27:25:2c
fc9/13 1 0xb200e1 21:00:00:04:cf:4c:18:61 20:00:00:04:cf:4c:18:61
fc9/13 1 0xb200d1 21:00:00:04:cf:4c:18:64 20:00:00:04:cf:4c:18:64
fc9/13 1 0xb200ce 21:00:00:04:cf:4c:16:fb 20:00:00:04:cf:4c:16:fb
fc9/13 1 0xb200cd 21:00:00:04:cf:4c:18:f7 20:00:00:04:cf:4c:18:f7
Total number of flogi = 6.
The following example displays the FLOGI interface.
switch#
show flogi database interface fc 1/11
INTERFACE VSAN FCID PORT NAME NODE NAME
-------------------- ---- -------- ----------------------- ---------------------
fc9/13 1 0xa002ef 21:00:00:20:37:18:17:d2 20:00:00:20:37:18:17:d2
fc9/13 1 0xa002e8 21:00:00:20:37:38:a7:c1 20:00:00:20:37:38:a7:c1
fc9/13 1 0xa002e4 21:00:00:20:37:6b:d7:18 20:00:00:20:37:6b:d7:18
fc9/13 1 0xa002e2 21:00:00:20:37:18:d2:45 20:00:00:20:37:18:d2:45
fc9/13 1 0xa002e1 21:00:00:20:37:39:90:6a 20:00:00:20:37:39:90:6a
fc9/13 1 0xa002e0 21:00:00:20:37:36:0b:4d 20:00:00:20:37:36:0b:4d
fc9/13 1 0xa002dc 21:00:00:20:37:5a:5b:27 20:00:00:20:37:5a:5b:27
fc9/13 1 0xa002da 21:00:00:20:37:18:6f:90 20:00:00:20:37:18:6f:90
fc9/13 1 0xa002d9 21:00:00:20:37:5b:cf:b9 20:00:00:20:37:5b:cf:b9
fc9/13 1 0xa002d6 21:00:00:20:37:46:78:97 20:00:00:20:37:46:78:97
Total number of flogi = 10.
The following example displays the FLOGI VSAN.
switch#
show flogi database vsan 1
---------------------------------------------------------------------------
INTERFACE VSAN FCID PORT NAME NODE NAME
---------------------------------------------------------------------------
fc9/13 1 0xef02ef 22:00:00:20:37:18:17:d2 20:00:00:20:37:18:17:d2
fc9/13 1 0xef02e8 22:00:00:20:37:38:a7:c1 20:00:00:20:37:38:a7:c1
fc9/13 1 0xef02e4 22:00:00:20:37:6b:d7:18 20:00:00:20:37:6b:d7:18
fc9/13 1 0xef02e2 22:00:00:20:37:18:d2:45 20:00:00:20:37:18:d2:45
fc9/13 1 0xef02e1 22:00:00:20:37:39:90:6a 20:00:00:20:37:39:90:6a
fc9/13 1 0xef02e0 22:00:00:20:37:36:0b:4d 20:00:00:20:37:36:0b:4d
fc9/13 1 0xef02dc 22:00:00:20:37:5a:5b:27 20:00:00:20:37:5a:5b:27
fc9/13 1 0xef02da 22:00:00:20:37:18:6f:90 20:00:00:20:37:18:6f:90
fc9/13 1 0xef02d9 22:00:00:20:37:5b:cf:b9 20:00:00:20:37:5b:cf:b9
fc9/13 1 0xef02d6 22:00:00:20:37:46:78:97 20:00:00:20:37:46:78:97
Total number of flogi = 10.
The following example displays the FLOGI FCID.
switch#
show flogi database fcid 0xef02e2
---------------------------------------------------------------------------
INTERFACE VSAN FCID PORT NAME NODE NAME