S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
20-29
Cisco MDS 9000 Family Command Reference
OL-18089-01, Cisco MDS NX-OS Release 4.x
Chapter 20 R Commands
rmon hcalarm
rmon hcalarm
To configure a 64-bit remote monitoring (RMON) high-capacity alarm (hcalarm), use the
rmon hcalarm
command
in configuration mode. To delete an rmon hcalarm, use the
no
form of the command.
rmon hcalarm
alarm-number mib-object sample-interval
{absolute | delta}
{rising-threshold-high
value
rising-threshold-low
value
[
rising-event
]
[falling-threshold-high
value
falling-threshold-low
value
[
falling-event
]] |
falling-threshold-high
value
falling-threshold-low
value
[
falling-event
]}
[owner
alarm-owner
]
no rmon hcalarm
alarm-number
Syntax Description
Defaults
64-bit alarms.
Command Modes
Configuration mode
Command History
alarm-number
Specifies the RMON hcalarm number. The range is 1 to 65535.
mib-object
Specifies the MIB object to monitor. Maximum length is 80 characters.
Note
The MIB object identifier must be fully numbered, dotted-decimal
notation, not the text string description.
sample-interval
Specifies the sample interval in seconds. The range is 1 to 65535.
absolute
Tests each sample directly.
delta
Tests the difference (delta) between the current and previous sample.
rising-threshold-high
value
Configures the upper 32 bits of the 64-bit rising threshold value. The range
is 0 to 4294967295.
rising-threshold-low
value
Configures the lower 32 bits of the 64-bit rising threshold value. The range
is 0 to 4294967295.
rising-event
(Optional) Specifies the event to trigger on rising threshold crossing. The
range is 1 to 65535.
falling-threshold-high
value
Configures the upper 32 bits of the 64-bit falling threshold value. The range
is 0 to 4294967295.
falling-threshold-low
value
Configures the lower 32 bits of the 64-bit falling threshold value. The range
is 0 to 4294967295.
falling-event
(Optional) Specifies the event to trigger on falling threshold crossing. The
range is 0 to 65535.
owner
alarm-owner
(Optional) Specifies an owner for the alarm. Maximum size is 80 characters.
Release
Modification
3.0(1)
This command was introduced.