S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
22-367
Cisco MDS 9000 Family Command Reference
OL-18089-01, Cisco MDS NX-OS Release 4.x
Chapter 22 Show Commands
show scsi-flow
Initiator Linecard Status: success
Target Linecard Status: success
Feature Status:
---------------
Write-Acceleration enabled
Write-Acceleration Buffers: 1024
Configuration Status: success
Table 22-8
describes the significant fields shown in the
show scsi-flow
command output.
The following example displays SCSI flow services configuration for a specific SCSI flow identifier.
switch#
show scsi-flow flow-id 3
Flow Id: 3
Initiator VSAN: 101
Initiator WWN: 21:00:00:e0:8b:05:76:28
Target VSAN: 102
Target WWN: 21:00:00:20:37:38:7f:7d
Target LUN: ALL LUNs
Flow Verification Status:
-------------------------
Initiator Verification Status: success
Target Verification Status: success
Initiator Linecard Status: success
Target Linecard Status: success
Feature Status:
---------------
Write-Acceleration enabled
Write-Acceleration Buffers: 1024
Configuration Status: success
Statistics enabled
Configuration Status: success
The following example displays SCSI flow services statistics for all SCSI flow identifiers.
switch#
show scsi-flow statistics
Stats for flow-id 4 LUN=0x0000
------------------------------
Read Stats
I/O Total count=2
Table 22-8
show scsi-flow Field Descriptions
Field
Description
Initiator Verification
Status
Verifies that the name server, FLOGI server, and zone server information
for the initiator on the local switch are correct.
Target Verification Status Verifies that the names sever and zone server information for the target
on the local switch are correct.
Initiator Linecard Status
Verifies that the initiator is connected to an SSM and if DPP provisioning
is enabled for the module.
Target Linecard Status
Verifies in the following order:
1. The target switch sees the proper name server and zone server
information for the initiator.
2. The target switch sees the proper name server, FLOGI server and zone
server information for the target.
3. The target is connected to an SSM and if DPP provisioning is enabled
for that module.