S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
22-408
Cisco MDS 9000 Family Command Reference
OL-18089-01, Cisco MDS NX-OS Release 4.x
Chapter 22 Show Commands
show system health
Table 22-10
describes the status value for each module
Note
Interface-specific counters will remain at zero unless the module-specific loopback test reports
errors or failures.
The following example displays the loopback test time log for all modules.
switch#
show system health statistics loopback timelog
-----------------------------------------------------------------
Mod Samples Min(usecs) Max(usecs) Ave(usecs)
1 1872 149 364 222
3 1862 415 743 549
8 1865 134 455 349
-----------------------------------------------------------------
The following example displays the loopback test statistics for a specified module.
switch#
show system health statistics loopback module 8 timelog
-----------------------------------------------------------------
Mod Samples Min(usecs) Max(usecs) Ave(usecs)
8 1867 134 455 349
-----------------------------------------------------------------
Table 22-10
Shows the Status Value for Each Module
Status
Description
Running
OHMS test is running and there are no errors
detected.
Failing
OHMS test has started to fail or in the process of
failing.
Failed
OHMS test failed.
Stopped
OHMS test stopped. This is a transient state (for
example, during upgrades and downgrades).
Exited
OHMS test process or thread exited while running
the test.
Not Configured
OHMS test configured to not run on the module.
Int Failed
OHMS test failed because of internal failure.
Diag Failed
OHMS test failed in performing diagnostics.
Suspended
OHMS test suspended because of too many error
conditions. OHMS cannot complete the test to
determine the hardware status.
Halted
OHMS test is halted because the test is not
intended to run on the module. (for example, a
specific hardware of which a test is operating is
not found on the module).
Enabled
OHMS is disabled by the user but not the test.
Disabled
OHMS test is disabled by the user.