MagnaTran 7.1 User’s Manual
Operational Interfaces
MN-003-1600-00
MISC I/O Communications
Brooks Automation
Revision 2.2
5-19
Marathon Express I/O
The following table shows the MagnaTran 7 connector assignments used exclusively
in the Brooks Automation Marathon Express Integrated Platform wafer transfer sys-
tem.
The MagnaTran 7 connector is a high side discrete interface (as described in
) and includes the serial interface to the robot on the same connector.
The state of the peripheral devices such as slot valves, robot extend enable, robot
retract enable and wafer presence sensor in the Marathon Express Transport Chamber
are monitored.
Cable connections are included with the Marathon Express system. See also, the
Brooks Automation Marathon Express User’s Manual.
Table 5-8: Marathon Express Connector
Pin
com
Signal Name
Pin
com
Signal Name
Pin
com
Signal Name
1
DIO
AL.RE-EN
18
DIO
SS.AL
34
DIO
AL.RNE
2
DIO
BL.RE-EN
19
DIO
SS.BL
35
DIO
BL.RNE
3
DIO
P1-RE-EN
20
DIO
SS.P1
36
DIO
P1.RNE
4
DIO
P2.RE-EN
21
DIO
SS.P2
37
DIO
P2.RNE
5
DIO
P3.RE-EN
22
DIO
SS.P3
38
DIO
P3.RNE
6
DIO
P4.RE-EN
23
DIO
SS.P4
39
DIO
P4.RNE
7
DIO
P5.RE-EN
24
DIO
SS.P5
40
DIO
P5.RNE
8
DIO
P6.RE-EN
25
DIO
SS.P6
41
DIO
P6.RNE
9
DIO
SV.AL-OPND
26
DIO
SV.P1-OPND
42
DIO
SV.BL-OPND
10
DIO
SV.P2-OPND
27
DIO
SV.P4-OPND
43
DIO
SV.P3-OPND
11
DIO
SV.P5-OPND
28
DIO
PP.CS-OPND
44
DIO
SV.P6-OPND
12
DIO
CS.RNE
29
DIO
PP.CS-CLSD
45
DIO
RNE
13
DIO
30
+24VDC
46
14
DIO
31
+24VDC
47
15
+24V RTN
32
+24V RTN
48
16
SER
RSGND.M7
33
SER
RXD.RB/T+
49
SER
TXD.RB/T-
17
SER
RTS.RB/R-
50
SER