Command Reference
MagnaTran 7.1 User’s Manual
Set Communication
MN-003-1600-00
Brooks Automation
8-124
Revision 2.2
UP|DN= Z location
NOTE:
Set commands only store the specified setting in RAM. Resetting the robot will
cause the original setting to be loaded from non-volatile memory. See the corre-
sponding STORE command to save permanently save parameters.
See Also:
RQ COMM, STORE COMM
Examples
The following example sets the serial I/O communications mode in RAM to Monitor.
SET COMM M/B MON
The following example sets the command execution mode in RAM to Background.
SET COMM FLOW BKG
The following example sets both the communications mode to Monitor and the com-
mand execution mode to Background.
SET COMM M/B MON FLOW BKG
The following example sets both the serial I/O communications mode and the com-
mand execution mode using the ALL specifier.
SET COMM ALL MON BKG
The following example displays the Automatic Data Reporting string after a PICK 1 is
performed:
PICK 1
RE 01 0001 DN
EX 01 0001 DN
EX 01 0001 UP
RE 01 0001 UP