MagnaTran 7.1 User’s Manual
Maintenance and Repair
MN-003-1600-00
Power Pak Replacement
Brooks Automation
Revision 2.2
9-63
Power Pak Replacement
The Power Pak was designed to be replaced quickly and without setup. The Power
Pak has no user-replaceable components inside.
Required Tools and Test Equipment
•
No tools are required to replace the Power Pak
•
Small screwdriver is required to remove and replace the cables
•
Initial installation requires a set of Allen wrenches in metric sizes
Removal Procedure
WARNING
When equipment is off and power is secured per facilities lockout/
tagout procedure, the unit is classified as a Type 1 hazard category.
See
.
1.
Turn of the power supply to the robot and unplug the power and communica-
tion connections.
DANGER
All power to the unit must be disconnected per the facilities’ lockout/
tagout procedure before servicing to prevent the risk of electrical
shock.
2.
Two fasteners hold the Power Pak to the robot. These fasteners are located
below the MagnaTran 7.
Pull the Power Pak to align the fasteners to the holes of the Power Pak. See
3.
Tip the Power Pak down slightly to clear the fasteners and pull the Pak away
from the robot.