Troubleshooting
MagnaTran 7.1 User’s Manual
Main Power Grounding Scheme Requirements
MN-003-1600-00
Brooks Automation
10-32
Revision 2.2
Main Power Grounding Scheme Requirements
1.
Ensure that the robot’s 24 volt power supply is unplugged and turn power
OFF.
2.
Connect the P3 connector of the MagnaTran 7 power cable (002-2198-01) to the
input power connector of the robot .
3.
Secure the +24 volt power lead (red) of the MagnaTran 7 power cable to the +24
volt DC terminal of the power supply. Reference Figure 1.
4.
Secure the +24 volt return lead (black), earth ground lead (green), and the logic
ground lead (white) of the MagnaTran 7 power cable to the 24 volt return ter-
minal of the power supply. Reference Figure 1.
5.
Ensure that the 24 volt return terminal of the power supply is connected to the
power supply’s chassis ground. Reference Figure 1.
6.
Plug the robot’s 24 volt DC power supply in and turn power ON.