Alignment and Calibration
MagnaTran 7.1 User’s Manual
Robot Alignment
MN-003-1600-00
Brooks Automation
7-4
Revision 2.2
Alignment Procedure
This section describes the procedure for preparing the Brooks Automation Magna-
Tran 7 Robot for alignment.
Prior to beginning the alignment procedure, verify the following:
•
Read and understand
before beginning this procedure.
•
Read the alignment procedure thoroughly.
•
Become familiar with all attached subsystems, including the CDM, and the
Command Set.
•
Verify that the entire system is level.
•
Ensure the system is at room temperature and at atmospheric pressure.
NOTE:
Ensure that the system the robot is installed in is level before starting the alignment
procedure. To ensure accuracy and repeatability do not “home” the robot during
the alignment procedure.
It is crucial that the alignment is performed in the given sequence for maximum oper-
ating performance of the robot.
1.
Power up and initialize the MagnaTran 7 robot.
2.
Power up and initialize all devices the robot will interface with.
3.
Follow the remaining alignment procedures provided in this chapter in the
order presented.