Command Reference
MagnaTran 7.1 User’s Manual
Store Warning CDM Status
MN-003-1600-00
Brooks Automation
8-172
Revision 2.2
Store Warning CDM Status
Purpose
To store the current setting for the warning feature of the CDM.
Format
STORE WARN CDM
Description
This command is used to store the current CDM warning feature status. If the feature
is enabled, the host will receive an unsolicited error message “CDM IS IN CON-
TROL” when the CDM is turned on.
NOTE:
Store commands store the current setting in RAM to non-volatile memory. Reset-
ting the robot will cause the new setting to be loaded from non-volatile memory.