Command Reference
MagnaTran 7.1 User’s Manual
Request Communication
MN-003-1600-00
Brooks Automation
8-72
Revision 2.2
OFF
Checksum disabled
data_rep:
Reports the data reporting flag. This command in supplied for VT5 com-
patibility only. See
Appendix D: Robot Compatibility on page 11-5
.
AUT Automatic mode
REQ Request mode
errorlevel:
Reports the error reporting level.
1 - 5
Automatic mode
baudrate:
Reports the baud rate.
9600 Serial communication
19200 LonWorks
NOTE:
At least one argument must be specified. If the ALL argument is specified no other
argument name may be specified.
Description
Requests the specified I/O configuration in RAM.
NOTE:
Request commands display the current value stored in RAM.
See Also:
SET COMM, STORE COMM
Examples
The following example requests the current serial I/O communications mode. The
status is returned as “Monitor Mode”.
RQ COMM M/B
COMM MON
The following example requests the current command execution mode. The current
status is returned as “Background”.
RQ COMM FLOW
COMM BKG