Command Reference
MagnaTran 7.1 User’s Manual
Set Sync Zero
MN-003-1600-00
Brooks Automation
8-150
Revision 2.2
Set Sync Zero
Purpose
Sets the zero or Home reference for the theta and Z-axes.
Format
SET SYNC ZERO position
Arguments
position:
The axis to be set:
T1: Theta axis outer shaft
T2: Theta axis inner shaft
Z: Z-Axis
ALL: T1, T2, Z
Description
CAUTION
The SET SYNC ZERO command is NOT used in the normal operation
of the robot. Stored values may be lost if used improperly.
The MagnaTran 7 robot Home position encoder counts can be reset.
See Also:
See
Restore the Home Position to the Factory Settings on page 9-71
for
instructions on the proper use of this command.