Operational Interfaces
MagnaTran 7.1 User’s Manual
Power Connections
MN-003-1600-00
Brooks Automation
5-4
Revision 2.2
* If the robot is configured for the PowerPak, but the PowerPak has been removed,
pins 1, 2, and 5 must be jumpered together to defeat the battery interlocks.
Table 5-1: Power Connector ITT Pin Assignments
Pin ID
Purpose
Function
A1
no connection
A2
Earth Ground
Connected to Earth GND at Power
Supply.
Internal Earth GND to robot frame
chassis bolt
A3
+24V RET
Connected to Earth GND at Power
Supply and RET post on power sup-
ply.
A4
+24V
20 Amps
1
no connection
*PowerPak defeat jumper
2
no connection
3
no connection
4
no connection
5
no connection
The power connection used is an
ITT Cannon DBM9W4PK87 connec-
tor on the robot and the mating ITT
Cannon DAME7W2SA197 connec-
tor, DBM9W45A109 shell,
DM53744-6 contacts on the power
cable. The pin-out for the power
cable is provided in
.
Figure 5-3: Power Connector Pin-Out
A1
A2
A3
A4
1
2
3
4
5