Find Zero
MN-003-1600-00
Brooks Automation
8-32
Revision 2.2
Find Zero
Purpose
Changes the zero or Home reference for the Theta Axis.
CAUTION
This command is NOT used in the normal operation of the robot. Call
Brooks Automation Technical Support for instructions on the correct
use of this command.
Format
FIND ZERO position
Arguments
position:
The axis to be changed.
T: Theta axis
Description
The MagnaTran 7 robot Home position may be changed from the factory settings to
accommodate the users requirements.
NOTE:
The minimum Z value is established with a mechanical adjustment of the home
flag. See
Z Hard Stop and Overtravel Limit Switch Adjustment on page 9-53
for
setting the Z value.
CAUTION
Once these positions are changed, all stations must be retaught.
See Also:
Reset the Home Position to the User Preference on page 9-73