MagnaTran 7.1 User’s Manual
Maintenance and Repair
MN-003-1600-00
Z Hard Stop and Overtravel Limit Switch Adjustment
Brooks Automation
Revision 2.2
9-53
Z Hard Stop and Overtravel Limit Switch Adjustment
The following procedure is used when the Z Home position is reset. This procedure
adjusts the Z hard stops and the Z microswitch to the new Z Home position.
NOTE:
It is not necessary to remove the robot to perform this repair procedure.
1.
Turn off power to the robot and disconnect the power and communications
connections to the robot.
2.
Remove the protective covers as shown in
.
CAUTION
Observe proper ESD precautions when handling any electronic
device.
3.
Reconnect robot power cable and CDM or serial communications cable.
Power up robot.
4.
Establish communications with the robot with the CDM or serial port.
WARNING
When equipment is energized and live circuits are uncovered, the
robot is at a Type 3 hazard category. See
.