Command Reference
MagnaTran 7.1 User’s Manual
Error Code Reference
MN-003-1600-00
Brooks Automation
8-182
Revision 2.2
board. If FETs are not shorted, replace PC104 Card. Refer to
Error 608:
Robot halting.
A “halt” command has been issued to the robot which stops robot motion. If the robot is operat-
ing in the compatibility mode: COMPATIBILITY HALT VT5, then the robot must be homed
prior to its next move. If the robot is operating in the compatibility mode: COMPATIBILITY
HALT MAG6, then the robot will remain referenced and is ready for the next move.
Error 610:
Emergency stop on.
The EMER_STOP interlock for the robot has been activated.
•
Refer to
Operational Interlocks on page 6-23
.
•
The PowerPak accessory has been programmed using the EMER_STOP interlock
function but the PowerPak is not properly connected to the robot. Check PowerPak
cables for proper connection and continuity.
•
Verify that a robot emergency off (EMO) button has been activated and deactivate as
appropriate.
•
Check host controller software.
•
Refer to
Operational Interlock Related Issues on page 10-20
Error 611:
Warning, CDM has been turned on.
Error 612:
Warning, CDM has been turned off.
Error 613:
UPS Battery is low.
The UPS_BATTERY_SEN interlock for the robot has been activated.
•
Refer to
PowerPak Power Fault Manager on page 6-84
for correct operation. The Pow-
erPak accessory is programmed using the UPS_BATTERY_SEN interlock function,
and the internal PowerPak battery voltage is less than 23.5 volts. Recharge or replace
PowerPak as appropriate.
•
Check host controller software.
•
Refer to
Operational Interlock Related Issues on page 10-20
Error 652:
Unable to create command dispatcher.
Error 653:
Unexpected mail received by dispatcher.
Error 654:
Unknown command.
Error 655:
Bad parameter passed to dispatcher.
Error 656:
Command processing has finished.
Robot Wafer Sensor Errors
Error 700:
Wafer detected.
Error 701:
No Wafer detected.
Error 705:
Wafer missing
Ensure wafer is present in VCE or process module prior to issuing PICK/PLACE/GOTO/
XFER command.