Troubleshooting
MagnaTran 7.1 User’s Manual
Z Brake Binding Test
MN-003-1600-00
Brooks Automation
10-28
Revision 2.2
7.
After the robot has finished free-falling in the Z direction, measure the distance
between the bottom of the robot armset and the top of the transfer chamber.
Record the measurement value.
8.
If the distance measured is less than 4 mm, then the Z brake is not binding. If
the distance is greater than 4 mm, call Brooks Technical Support.
9.
Reference the robot by issuing the command: HOME ALL.
Procedure is complete.