Страница 2: ...e Table of gas types p 2 General Warnings p 19 Normes et Directives p 19 Installation and Gas Electric connection p 20 General Warnings for the Maintenance p 24 Gas Bratt Pans p 180 199 Cooking equipm...

Страница 3: ...n mbar PMAX mbar G20 Methane 2H 20 17 25 G25 Methane 2ELL 20 17 25 G25 Methane 2E 25 20 30 G25 1 Methane 2HS 25 20 30 G25 3 Methane 2EK 25 20 30 G30 Butane 3B P 28 30 25 35 G30 Butane 3 28 30 20 35 G3...

Страница 4: ...t be obstructed Children should be supervised to ensure they do not play with the appliance Before connecting the device make sure that the plate specifications correspond to the electrical and gas su...

Страница 5: ...es for home professional use and industry SVGW Regulation of cantonal applications in Switzerland for ex fireproof regulations And the particular reference norms Declaration of compliance The manufact...

Страница 6: ...mes evacuation Type A1 gas appliances The deep fat fryers are type A1 gas appliances and it is not necessary to connect directly to an evacuation pipe for combustion products The products of combustio...

Страница 7: ...gs Gas Connection Before connecting the appliance it is necessary to check that the type of gas available corresponds to the type of gas the appliance has been set for In the event that they do not co...

Страница 8: ...nly a single appliance to each switch In some cases after long periods of inactivity or in case of a new installation it is possible that the appliance switches off during the setting up The main reas...

Страница 9: ...supply company The reading has to be done when the appliance is already in function Checking pilot burner Check the flame of the pilot burner which must be neither too short nor too high but must lap...

Страница 10: ...B appliances following the prescriptions in force in the country of installation The gas tap should be lubricated but this operation is quite difficult and its results are not very reliable Therefore...

Страница 11: ...atures p 181 Burners Features p 182 Dimensions p 185 Description of appliances p 199 Regulation using a different type of gas p 199 Substituting components p 201 Operating anomalies p 201 Instructions...

Страница 12: ...Capacit cuve Tank capacity l 52 5 52 5 Gas Gaz B KW 12 5 12 5 Typ Type Typ A A1 A1 GPL LPG G30 D Kg h 0 986 0 986 Erdgas Methane G20 C m3 h 1 322 1 322 Luft Air m3 h 25 38 Gasanschluss Racc Gaz Gas f...

Страница 13: ...mme Piloto N Aria Air Luft Aire x mm BRUCIATORE BR LEUR BURNER BRENNER QUEMADOR Liquid Gas PLG 12 50 AL125 x 2 16 2 1 5 G31 Tabella Tableau Table Tafel Tabla 77 CY MT HU NL CAT I3B P 29mbar Tipo gas T...

Страница 14: ...EMADOR Natural Methan gas 12 50 AL190 x 2 27 2 0 5 G20 Liquid gas LPG 12 50 AL125 x 2 16 2 1 5 G30 G31 Tabella Tableau Table Tafel Tabla 81 CH SK DE AT CAT 2H3B P 50 mbar Tipo gas Type gaz Gas Type Ga...

Страница 15: ...as 12 50 AL190 x 2 27 2 0 5 G20 Natural Methan gas 12 50 AL210 x 2 27 2 0 5 G25 Liquid gas LPG 12 50 AL105R x 2 16 2 1 5 G30 G31 Tabella Tableau Table Tafel Tabla 85 NL CAT II2EK3B P Tipo gas Type gaz...

Страница 16: ...loto N Aria Air Luf t Aire x mm BRUCIATORE BR LEUR BURNER BRENNER QUEMADOR module Natural Methane Gas 12 50 AL190 x 2 27 2 0 5 G20 Liquid Gas LPG 12 50 AL125 x 2 16 2 1 5 G30 G31 Town Gas 11 80 AL380...

Страница 17: ...nge to another gas type it is necessary to substitute the nozzles of the main burners and of the pilot burner following the instructions in the following paragraphs The nozzle type to be installed can...

Страница 18: ...air of the burner After substituting the burner nozzle the primary air must be regulated Therefore loosen the screw 9 that fixes the bush 10 bring value X to the correct measurement tighten the screw...

Страница 19: ...stall everything following the inverse sequence For better sealing it is advisable to screw the connections 9 to the valve by interposing a clamping screw Thermocouple In order to replace the safety v...

Страница 20: ...power supply Check the condition of the heating element Check the thermostat No indicator light Check the power supply Check the light bulb Slow and or inadequate heating Check the setting of the ther...

Страница 21: ...operation must always be carried out under surveillance If the lid is kept closed during cooking be careful when you lift it there is a risk to get burnt due to the steam produced inside the cooking v...

Страница 22: ...for a long time it is advisable to turn off the gas tap Then disconnect the main electricity supply wipe all stainless steel surfaces with a cloth soaked in Vaseline oil in order to give it a protect...