20/208
TECHNICAL FEATURES
The following instructions for set up and functioning refer to gas and mixed appliances belonging to
categories I
2H,
I
3P,
I
3B/P
, II
HS3B/P,
II
2E3PB/P
II
2H3+
, II
2H3B/P
,
with a power pressure for Butane/Propane
(G30-G31) of 30/50 mbar and Methane (G20) of 20 mbar. The DATA PLATE showing all the
appliance information is to be found inside the right or left side of the control panel, depending on
the model.
The appliances have been checked in accordance with the European directives down below:
2014/35/UE
- Low Tension (LVD)
2014/30/UE
- Electromagnetic Compatibility (EMC)
2016/426/UE
- Gas Appliances (GAR)
2006/42/EC
- Machinery directive
2011/65/CE
- Rohs
1935/2004/UE
- Food Contact Material (MOCA)
SVGW Directive G1 Directive for the installation of methane gas appliances in buildings
SVGW Norms L1
Norms for the installation of liquid gas appliances for home, professional use
and industry
SVGW Regulation of cantonal applications in Switzerland (for ex. fireproof regulations)
And the particular reference norms.
Declaration of compliance
The manufacturer declares that the appliances of their production meet the above mentioned EEC
directives and requires that installation be done observing the norms in force, particularly regarding
the system for letting out fumes and air exchange.
PROVISIONS FOR INSTALLATION
Place
It is advisable to install the appliance in a well-ventilated
room or under an extractor hood. The appliance may be
installed as a single unit or together with others. In both
cases, if it is installed near a wall of inflammable
material, a minimum distance according the series (see
figure) from the side and back walls must be observed.
In the event that it is not possible to observe this distance,
protective measures must be taken (e.g. use of sheets of
refractory material) which ensure that the
temperature of the walls is within the established
safety limits.
Norms and provisions