X20 system modules • Motor controllers • X20MM2436
1914
X20 system User's Manual 3.10
Product ID
X20MM2436
Nominal voltage
24 VDC
Input voltage
24 VDC (-15% / +20%)
Input current at 24 VDC
Approx. 1.3 mA
Input filter
Hardware
<5 µs
Software
-
Connection type
1-wire connections
Input circuit
Sink
Additional functions
2x AB incremental encoder, 1x ABR counter, 2x event counter, 2x period duration/gate measurement
Input resistance
Typ. 18 kΩ
Switching threshold
Low
<5 VDC
High
>15 VDC
Isolation voltage between channel and bus
500 V
eff
AB incremental encoder
Quantity
2
Encoder inputs
24 V, asymmetrical
Counter size
16-bit
Input frequency
Max. 50 kHz
Evaluation
4x
Signal form
Square wave pulse
PWM output
Quantity
2
Nominal voltage
24 to 39 VDC ±25%
Nominal current
3 A
Maximum current
3.5 A (2 s)
PWM frequency
15 Hz to 50 kHz
Actuator supply
Supply
External
Fuse
Required line fuse: Max. 10 A, slow-blow
Output protection
Thermal cutoff for overcurrent and short circuit
Design
H bridge
Configurable dither
Amplitude, frequency
Period resolution
16-bit, min. 20 μs
Phase shift PWM1 to PWM2
180°
DC bus capacitance
100 μF
PWM pulse width
PWM mode
15-bit + sign ≥10 ns
Current mode
15-bit + sign ≥10 ns
Isolation voltage between channel and bus
500 V
eff
Operating conditions
Mounting orientation
Horizontal
Yes
Installation at elevations above sea level
0 to 2000 m
No limitations
>2000 m
Reduction of ambient temperature by 0.5°C per 100 m
EN 60529 protection
IP20
Environmental conditions
Temperature
Operation
Horizontal installation
0 to 50°C
Vertical installation
Not permitted
Derating
See section "Derating"
Storage
-25 to 70°C
Transport
-25 to 70°C
Relative humidity
Operation
5 to 95%, non-condensing
Storage
5 to 95%, non-condensing
Transport
5 to 95%, non-condensing
Mechanical characteristics
Note
Order 1x X20TB12 terminal block separately
Order 1x X20BM31 bus module separately
Spacing
25
+0.2
mm
Table 692: X20MM2436 - Technical data