X20 system modules • Analog output modules • X20AO2632-1
470
X20 system User's Manual 3.10
4.4.6.8 Register description
4.4.6.8.1 Function model 0 - Standard
Read
Write
Register
Name
Data type
Cyclic
Non-cyclic
Cyclic
Non-cyclic
Analog output - Configuration
0
UINT
●
594
598
UINT
●
Analog output - Communication
2
4
INT
●
457
SINT
●
802
810
INT
●
804
812
DINT
●
Enabling/disabling the output channels
USINT
AnalogOutput01Enable, ~Readback
Bit 0
833
AnalogOutput02Enable, ~Readback
Bit 1
●
●
USINT
AnalogOutput01OK
Bit 0
835
AnalogOutput02OK
Bit 1
●
4.4.6.8.2 Function model 254 - Bus controller
Read
Write
Register
Offset
1)
Name
Data type
Cyclic
Non-cyclic
Cyclic
Non-cyclic
Analog output - Configuration
0
-
UINT
●
Analog output - Communication
2
4
0
2
INT
●
1)
The offset specifies the position of the register within the CAN object.
4.4.6.8.3 General information
The module provides two analog outputs. Each channel can output a voltage range of ±11 V or a current range
of 0 to 22 mA.
The module also has a time-based watchdog monitor. The user can activate this feature channel-by-channel as
needed.