X20 system modules • Module overview: Alphabetically
X20 system User's Manual 3.10
117
Product ID
Short description
on page
X20 bus base with 1 expansion slot for X20 base module (BC, HB, ...) and an X20 auxiliary module (IF, HB, ...)
and X20 power supply module, X20AC0SL1/X20AC0SR1 X20 end plates left and right included
X20 bus base with 2 expansion slots for X20 base module (BC, HB, ...) and two X20 auxiliary modules (IF,
HB, ...) and X20 power supply module, X20AC0SL1/X20AC0SR1 X20 end plates left and right included
X20 bus controller, CANopen interface, order 1x TB2105 terminal block separately. Order bus base, power
supply module and terminal block separately.
X20 bus controller, CANopen interface, configuration supported by the B&R FieldbusDESIGNER, order 1x
TB2105 terminal block separately. Order bus base, power supply module and terminal block separately.
X20 bus controller, DeviceNet interface, order 1x TB2105 terminal block separately. Order bus base, power
supply module and terminal block separately.
X20 bus controller, PROFIBUS DP interface, 9-pin DSUB connection, order bus base, power supply module
and terminal block separately.
X20 bus controller, CAN I/O interface, order 1x TB2105 terminal block separately. Order bus base, power supply
module and terminal block separately.
X20 bus controller, POWERLINK interface, integrated 2x hub, 2x RJ45 connection, order bus base, power
supply module and terminal block separately.
X20 bus controller, Modbus/TCP or Modbus/UDP interface, integrated 2x switch, 2x RJ45 connection, order
bus base, power supply module and terminal block separately.
X20 bus controller, EtherNet/IP interface, integrated switch, web interface 2x RJ45 connection, order bus base,
power supply module and terminal block separately.
X20 bus controller, PROFINET interface, integrated 2x switch, 2x RJ45 connection, order bus base, power
supply module and terminal block separately.
X20 bus controller, EtherCAT interface, 2x RJ45 connection, order bus base, power supply module and terminal
block separately.
X20 bus controller, CANopen interface, 9-pin DSUB, configuration supported by the B&R FieldbusDESIGNER,
order 1x 7AC911.9 connector separately. Order bus base, power supply module and terminal block separately.
X20 bus controller, 1 POWERLINK interface, integrated 2-port hub, supports X20 interface module expansions,
2 RJ45, order bus base, power supply module and terminal block separately.
X20 bus controller, POWERLINK interface, integrated 2x hub, supports X20 hub module expansions, 2x RJ45
connection, order bus base, power supply module and terminal block separately.
X20 bus controller, POWERLINK interface, integrated compact link selector supports active X20 hub module
expansions, 2x RJ45 connection, order bus base, power supply module and terminal block separately.
X20 bus controller, EtherCAT interface, supports expansion with X20 EtherCAT junction modules, 2x RJ45
connection, order bus base, supply module and terminal separately!
X20 supply bus module, internal I/O supply interrupted to the left
X20 supply bus module with node number switch, internal I/O supply is isolated to the left
X20 bus module, 24 V coded, internal I/O supply is interconnected
X20 bus module, 240 V coded, internal I/O supply is interconnected
X20 bus module with node number switches, internal I/O supply is interconnected
X20 bus module for double-width modules, internal I/O supply is isolated to the left
X20 bus module for double-width modules, internal I/O supply is interconnected
X20 bus module, 240 V coded, for double wide modules, internal I/O supply is interconnected
X20 bus receiver, X2X Link, supply for X2X Link and internal I/O supply, X20 locking plates (left and right)
X20AC0SL1/X20AC0SR1 included
X20 bus transmitter, X2X Link, supply for internal I/O supply
X20 bus transmitter X2X Link, feed for internal I/O supply, X2X Link supply for X67 modules, reverse polari-
ty protection, short circuit protection, overload protection, parallel connection possible, redundancy operation
possible
X20 combination module, 1 AB incremental encoder, 24 V, 4 digital inputs 24 V, 4 channels 24 V configurable
as inputs or outputs, flexible digital controller logic
X20 resolver module, 14-bit resolver input, converter up to 12-bit ABR output
X20 analog input module for vibration measurement and analyse of condition monitoring exercises. 4 IEPE
analog input 51,5625 kHz sampling frequency 24 bit converter resolution
X20 universal mixed module, 4 digital inputs, 24 VDC, sink, 1-wire connections, 2 digital outputs, 0.5 A, source,
1-wire connections, 1 analog input, ±10 V or 0 to 20 mA / 4 to 20 mA, 12-bit resolution, 1 analog output, ±10 V /
0 to 20 mA, 12-bit resolution, 2 counters as event counters or gate measurement
X20 PWM module, 8 digital outputs for switching electromechanical loads, 0.6 A continuous current, 2 A peak
current, current monitoring, switching time detection
X20 CPU, compact CPU µP 16, 100 kB SRAM, 1 MB FlashPROM, support of RS232 and CAN according to
compact CPU base, order bus base, power supply module and terminal block separately
X20 CPU, compact CPU µP 16, 100 kB SRAM, 1 MB FlashPROM, support of RS232 and CAN according to
compact CPU base, 1 Ethernet interface 100 Base-T, order bus base, power supply module and terminal block
separately
X20 CPU, compact CPU µP 25, 100 kB SRAM, 1 MB FlashPROM, support of RS232 and CAN according to
compact CPU base, 3 Ethernet interface 750 Base-T, order bus base, power supply module and terminal block
separately
X20 CPU, x86 100 MHz Intel compatible, 32 MB DRAM, 128 kB SRAM, removable application memory: Com-
pactFlash, 1 insert slot for X20 interface modules, 2 USB interfaces, 1 RS232 interface, 1 Ethernet interface
10/100 Base-T, 1 POWERLINK interface, incl. supply module, 1 X20TB12 terminal block, slot cover and X20
locking plate (right) X20AC0SR1 included, order application memory separately.
X20 CPU, x86 100 MHz Intel compatible, 64 MB DRAM, 128 kB SRAM, removable application memory: Com-
pactFlash, 1 insert slot for X20 interface modules, 2 USB interfaces, 1 RS232 interface, 1 Ethernet interface
10/100 Base-T, 1 POWERLINK interface, incl. supply module, 1 X20TB12 terminal block, slot cover and X20
locking plate (right) X20AC0SR1 included, order application memory separately.
X20 CPU, ATOM 333 MHz compatible, 128 MB DDR2 RAM, 1 MB SRAM, removable application memory:
CompactFlash, 1 insert slot for X20 interface modules, 2 USB interfaces, 1 RS232 interface, 1 Ethernet interface
10/100/1000 Base-T, 1 POWERLINK interface, incl. supply module, 1 X20TB12 terminal block, slot cover and
X20 locking plate (right) X20AC0SR1 included, order application memory separately.