EN
www
.mobotix.com
HiRes Video Innovations – Made in Germany
The German company MOBOTIX AG is known as the leading pioneer in network camera technology and its decentralized concept has made
high-resolution video systems cost-efficient.
MOBOTIX AG • D-67722 Langmeil • Phone: +49 6302 9816-103 • Fax: +49 6302 9816-190 • [email protected]
Security-Vision-Systems
Quick Install
BellRFID
Bell Button Module with RFID
Technology for up to Five Parties
Module for MOBOTIX IP Video Door Station, keyless entry and
mailbox control, can be combined with the different bell button sets
MX-Bell1-Button-F1/F2/F3/F4/05/XL1
Free-of-charge printing service on
www.mobotix.com
> Support
• BellRFID base module with 1 admin and 5 user RFID cards
• Interchangeable bell button sets (not included)
• Integrated RFID technology for keyless entry
• Available colors: white, silver, dark gray, black, amber
• Usable with/without function button for mailbox control
• Up to 60 hrs backup power supply using DoorMaster (accessory)
Standard Connection: IP Video Door Station
with
BellRFID, InfoModule and DoorMaster
Installation and Initial Operation of the BellRFID
Available Bell Button Sets
(for all color variants)
The BellRFID module is installed in the exactly
same manner as the KeypadRFID module. Make
sure that you follow the steps for the different
hardware scenarios of the IP Video Door Station
(with/without DoorMaster) as described in the door
station’s
System Manual Part 1 for the KeypadRFID
(see below).
Note:
BellRFID and KeypadRFID can only be used
on one MxBus with a later software version of
the camera.
MOBOTIX BellRFID
MX-Bell1-Core
(in IP Video Door Station
triple frame white)
I/O Terminal
Sealing plug
Seal
MxBus terminal
Back view with cover removed
Door
2
6
MxBus (YSTY 0.8 mm – max. length: 50 m/55 yd)
Theft protection (YSTY 0.8 mm – max. length: 50 m/55 yd)
Door opener, door sensor, lock sensor
(YSTY 0.8 mm – max. length: 50 m/55 yd)
DoorMaster
2
RFID cards
for keyless entry included
(1 admin card, 5 user cards)
MX-Bell1-Core
31.578_EN_V4_01/2015
You can use the blue function button at the door station to listen to new mailbox
messages, record new announcements and activate/deactivate the mailbox.
Visitors can leave a message even without the function button. The remaining
mailbox features are easily controlled using the remote station of the door
station (i.e., MOBOTIX App).
Each BellRFID base module contains 6 RFID cards (1 admin, 5 user cards).
Each button set contains pre-cut name plates made of UV-resistant paper. If
required, you can replace the button sets later on – in the same base module!
In order to configure the system using BellRFID, the bell buttons are replaced
by a keypad insert, which is delivered with the base module.
The Jones
Family
MX-Bell1-Button-XL1
XL bell button
(no function button)
MX-Bell1-Button-F1
Large bell button
with function button
The Jones
Family
MX-Bell1-Button-F2
2 medium-size bell buttons
with function button
The Jones
Family
Dr. Jones, MD
MX-Bell1-Button-F4
4 small bell buttons
with function button
Cindy Jones
Thomas Jones
The Jones Family
Dr. Jones, MD
MX-Bell1-Button-F3
1 large, 2 small bell buttons
with function button
Cindy Jones
Thomas Jones
Dr. Jones, MD
MX-Bell1-Button-05
5 small bell buttons
(no function button)
Caroline Jones
Cindy Jones
Thomas Jones
The Jones Family
Dr. Jones, MD
Before starting the installation and initial operation, you should download part 1 and 2 of the door station’s
System Manual from the MOBOTIX website
(
www.mobotix.com
> Support > Manuals
).
If the installation of the IP Video Door Station with BellRFID is not followed by the initial operation right away, MOBOTIX recommends to remove the keypad
insert and to insert the button set before starting the installation. This way, the soft rubber surface of the BellRFID base module is well protected until the
module is brought into service (bell buttons are then replaced by the keypad insert). Note that the base module is weatherproof even without the bell
buttons.
When replacing the button set or exchanging name plates, you need to remove the module from the frame of the IP Video Door Station. Use the
blue MOBOTIX key for unlocking the module.
Make sure that you are activating the mechanical theft protection with the red turning knob
in the door station frame only
after you have finished the initial operation
(see the
Section «Mechanical Anti-Theft Protection Lock» in the
door station’s
System Manual Part 1).
In order to avoid having to remove the module and install it again, you should insert the proper name plates before starting the initial operation.
Use our free-of-charge printing service on
www.mobotix.com
in the
Support
section! Or use the supplied name plates made from sturdy specialty
paper and write the names using a UV-resistant marker.
Available Bell
Button Sets
(Accessory)
The Jones
Family
The Jones
Family
Dr. Jones, MD
Cindy Jones
Thomas Jones
Dr. Jones, MD
Cindy Jones
Thomas Jones
The Jones Family
Dr. Jones, MD
Cindy Jones
Thomas Jones
The Jones Family
Dr. Jones, MD
Caroline Jones
Cindy Jones
Thomas Jones
The Jones Family
Dr. Jones, MD
The Jones
Family
1. Insert the Name Plate(s)
Remove the silicon insert from the button. Recommendation: Take a suitable
tool without a sharp blade, cautiously insert it into the slot, gently press
inward and lift the tool as shown.
Insert the labeled or printed name plate as shown (the arrows at the side
are pointing upwards later on).
Place the silicon insert on top of the name plate, push it into the frame at
the top and at the bottom of the center, then push its sides into the frame.
Make sure that the silicon insert fits flush into the frame of the bell button
as shown to protect the name plate against humidity.
2. Insert the Module into the Door Station
You can use the BellRFID module as an alternative to the KeypadRFID (but
not yet side-by-side) in the frame of an IP Video Door Station. For installing
and wiring the module, follow the same steps as for the KeypadRFID.
Follow the description in the
Section «Installing the KeypadRFID Access
Module» of the door station’s System Manual Part 1. Likewise, the other
connection variants listed in the
Section «Overview: Connection and Wiring
Diagrams» (e.g., connecting an electrical door opener in a system without
DoorMaster).
Finish the installation of the BellRFID module by following the steps listed in
the
Section «Finishing the Installation» of the door station’s System Manual
Part 1. Similar to the KeypadRFID, the blue and the green status LEDs are
flashing (power supply OK, ready for auto configuration).
Installation Hint
When installing the module, insert it first on the right-hand
side. Then use two fingers and press on the left-hand
edge until the module clicks into the frame.
Caution: Only
press at the edge, never at the center of the module!
Make sure that the cabling is not pinched and damaged
when installing the module.
3. Execute Auto Configuration
Place the supplied keypad insert into the base module
(push it into the frame at the top, then push the bottom
into the module).
Start the auto configuration of the IP Video Door Station by executing the
steps listed in the
Section «Step 1: Performing the Auto Configuration» of
the door station’s
System Manual Part 2 (connect all devices, establish the
power supply and press the bell button of the camera module immediately
after the light and bell buttons are lighting up).
Once you have successfully completed the auto configuration, the white
camera illumination is on and the BellRFID shows the following status:
• The green status LED is flashing continuously, the blue LED flashes for a
short time before it extinguishes.
• The LED of the keypad behind the top right key (
OK
) is red.
Finish the auto configuration by executing the steps listed in the
Section
«Functional Test Part 1» of the door station’s System Manual Part 2.
4. Enter Super PIN and Confirm
The
Super PIN
is used to protect the system against misuse and also replaces
the factory default password (“
meinsm
”) as the new admin password. The
password is also used when adding the door station to the MOBOTIX App or
MxEasy, for example (user name is
admin
, new password is the
<Super
PIN>
). Select a Super PIN that has a minimum of 8 and a maximum of
16 digits (more and different digits make it more secure). For additional
information on the Super PIN, see the door station’s
System Manual Part 2.
Dr.
Dr.
Jon
es,
M
D
1
3
4
2
1
2
Click!
Cindy Jones
Thomas Jones
The Jones Family
Dr. Jones, MD
Indoor
Outdoor
For additional information on the other connection variants and for installing,
see the door station’s
System Manual Part 1 on
www.mobotix.com
> Support > Manuals
.
IP Video Door Station
BellRFID
InfoModule
Cindy Jones
Thomas Jones
The Jones Family
Dr. Jones, MD
Use our free-of-charge
Printing Service
on
w w w . m o b o t i x . c o m
,
Support
section!
Weatherproof (IP65)
–30 to +60
°C/–22 to +140
°F