The JA-110N-DIN Bus PG-DIN power output module  

The JA-110N-DIN Bus PG-DIN power output module 

1 / 1 

MLY51802 

The JA-110N-DIN is a component of the 

JABLOTRON 100 

system.  It provides a PG output power relay switch. It has been 
designed for mounting on a DIN rail and for switching mains-
powered output devices (up to 230V /16A). The module should  
be installed by a trained technician with a valid certificate issued by 
an authorized distributor. 

 

Installation 

The  module  has  been  designed  for  mounting  on  a  DIN  rail  in 

conformity with EN60715.  It is connected to a system bus through 
which  it is also powered.  It  has to be enrolled into the  system and 
occupies one position.

 

 

 

When connecting the module to the system 
digital bus, always switch the power off. 

If  the  module  is  installed  outside  the  guarded 
area, the JA-110T bus insulator should be used 
for the external section of

 

the wiring. 

Electrical  devices  can  only  be  connected 
by a trained technician.

 

 

 

Figure:  1 = bus terminals (CC-01(02) cable): +U red, GND black, A yellow, 

B green); 2 = red LED – relay triggering; 3 = yellow LED - failure;  

4 = production code;  5 = enrollment or manual trigger button;  

 6 = relay terminal; 

 

1. 

Install the module on a DIN rail. 

 

2. 

Connect  bus  wires  to  the  terminals  (1).  We  recommend  using  
a  CC–01  or  CC–02  cable  (supplied  by  Jablotron)  to  connect  
a module.

 

3. 

Proceed according to the control panel installation manual. Basic 
procedure:

 

a. When  the  relay  is  switched  on,  the  yellow  LED  (3)  starts 

flashing  repeatedly  to  indicate  that  it  has  not  been  enrolled  
to the system. 

b. 

Go to the 

F-Link

 program,  select the  required position  in the 

Devices tab

  and  launch  the  enrollment  mode  by  clicking  

on the 

Assign

 option. 

 

c. 

Press the 

Manual/Learn (enrollment) 

button (5) – the module 

is thus enrolled into the system and the yellow LED goes off.

 

 

4. Test  the  module  functioning.  When  the  module  is  switched  on, 

the red LED (2) starts to light. 

5. Connect  the  device  to  be  controlled  by  the  relay  to  the  relay 

output terminals (6). 

 

Setting of module properties 

Go  to  the 

Detectors 

window

 

in  the

 F-Link

  program.  When  you 

are  at  the  module  position,  use  the 

Internal settings

  option.

 

Set 

the following in the dialogue window: 

 

 

 

Manual control (5):

  Module  control  with  the  button  is  enabled  

as  a  default.  Function:  brief  pressing  of  the  button  triggers  the  relay 

(status) 

ON/OFF.  System  control  commands 

(on the bus)

  override 

the state selected with the button. Manual control is possible even 
in a situation when there is no communication with the control panel 
for  some  reason.  The  button  control  function  can  be  completely 
disabled in a dialog window.

 

Relay activation by a PG output:

  It  is  possible  to  select  module 

activation by one or more PG outputs. 

 

 

Notes: 

 

Multiple modules can be enrolled to the  system. The  number 
of modules is only limited by the number of devices and by the 
power consumption from the digital bus.

 

 

If communication  is lost  (A-B bus connections) for more than 
60s, the module relay switches to idle mode. 

 

The  module  can  also  be  enrolled  into  the  system  by  entering  its 
production code (4) in the F-Link program. All numbers should be 
entered (number format example: 1400-00-0000-0001). 

 

The  settings can  also be  set  in the 

F-Link

 - 

PG outputs

  tab

 – 

Activation 

button

 

Technical specifications 

Power 

from control panel digital bus 12 V (9…15 V)

 

Consumption in standby mode (relay off / on)  

5 mA /45 mA

 

Current consumption for cable selection 

45 mA

 

Relay  contact  capacity  (galvanically  separated  from  the  bus) 
– class protection II: 

Maximum acceptable output through voltage  250 V AC / 24 V DC

 

5HVLVWLYHORDGFRVij 

  

max.16 A

 

,QGXFWLYHFDSDFLWLYHORDGFRVij 

 

max. 8 A

 

Halogen lighting 

max. 1000 W

 

Minimum DC switched power 

384 W

 

Minimum DC output power 

0.5 W

 

Connected wire diameter 

max. 2x 1.5 mm

2

 

 

max. 1x 2.5 mm

2

 

Dimensions 

18 x 90 x 64 mm

 

Environment 

indoor general

 

Operating temperature range 

-15 to +50 °C

 

Degree of protection 

IP-20

 

Also complies with 

EN 50130-4, EN 55022,  

 

 

EN 60950-1, DIN rail EN60715 

 

 

JABLOTRON ALARMS a.s. hereby declares that the JA-110N-DIN 
is in compliance with the essential requirements and other relevant 
provisions of Directives 2006/95/EC and 2004/108/EC.  The original 
of the conformity assessment can be found at 

www.jablotron.com

 - 

Technical Support section

 

 

Note: