ATLAS 550 System Manual
Section 4 User Interface Guide
61200305L2-1B
© 2004 ADTRAN, Inc.
91
S
YSTEM
C
ONFIG
> B
ONDING
C
ONFIG
> TANULL T
IMER
Write security: 3; Read security: 5
Specifies the length of time the answering endpoint attempts to detect the BONDING negotiation pattern
from the originating endpoint before deciding the BONDING call has failed. It may be necessary to
shorten this timer if the DTE equipment using the BONDING module also has timer constraints for
completing non-BONDING parameter negotiation.
S
YSTEM
C
ONFIG
> B
ONDING
C
ONFIG
> TCID T
IMER
Write security: 3; Read security: 5
Specifies the length of time both endpoints attempt to negotiate an agreeable value for bearer channels (B
channels) and channel capacities before deciding the BONDING call has failed.
S
YSTEM
C
ONFIG
> B
ONDING
C
ONFIG
> C
ALL
S
TAGGER
Write security: 3; Read security: 5
Specifies the amount of delay between placing calls for outgoing BONDING sessions. The following call
stagger values are available:
N
O
S
TAGGER
,
500
MS
,
1
SEC
, and
2
SEC
S
YSTEM
C
ONFIG
> A
LARM
R
ELAY
R
ESET
Write security: 3; Read security: 5
Clears the Alarm Relay located on the back panel of the ATLAS 550. Activating the software Alarm Relay
Reset functions the same as manually pressing the
ACO
switch located on the ATLAS 550 front panel.
S
YSTEM
C
ONFIG
> A
LARM
R
ELAY
T
HRESHOLD
Write security: 3; Read security: 5
Defines which threshold sets the Alarm Relay. These thresholds include
C
RITICAL
,
M
AJOR
,
M
INOR
,
W
ARNING
, and
N
ORMAL
. If an alarm occurs that is greater than or equal to the threshold selected, the Alarm
Relay will set. For example, if the threshold is set for
M
AJOR
, then ALL
M
AJOR
alarms and ALL
C
RITICAL
alarms will set the Alarm Relay. There is one exception – setting the threshold to
N
ORMAL
will not set the
Alarm Relay for
N
ORMAL
events. No
N
ORMAL
events set the Alarm Relay.
Содержание ATLAS 550
Страница 16: ...Table of Contents ATLAS 550 System Manual 16 2004 ADTRAN Inc 61200305L2 1B ...
Страница 24: ...Section 1 System Description ATLAS 550 System Manual 24 2004 ADTRAN Inc 61200305L2 1B ...
Страница 62: ...Section 3 Network Turnup Procedure ATLAS 550 System Manual 62 2004 ADTRAN Inc 61200305L2 1B ...
Страница 308: ...Section 4 User Interface Guide ATLAS 550 System Manual 308 2004 ADTRAN Inc 61200305L2 1B ...
Страница 310: ...Section 5 Detail Level Procedures ATLAS 550 System Manual 310 2004 ADTRAN Inc 61200305L2 1B ...
Страница 320: ...Section 5 DLP 4 ATLAS 550 System Manual 320 2004 ADTRAN Inc 61200305L2 1B ...
Страница 326: ...Section 5 DLP 6 ATLAS 550 System Manual 326 2004 ADTRAN Inc 61200305L2 1B ...
Страница 330: ...Section 5 DLP 7 ATLAS 550 System Manual 330 2004 ADTRAN Inc 61200305L2 1B ...
Страница 348: ...Section 5 DLP 14 ATLAS 550 System Manual 348 2004 ADTRAN Inc 61200305L2 1B ...
Страница 351: ...61200305L2 1B 2004 ADTRAN Inc 351 CONFIGURATION GUIDES CFG 1 Dial Backup for Dedicated T1 Circuits 353 ...
Страница 352: ...Section 6 Configuration Guides ATLAS 550 System Manual 352 2004 ADTRAN Inc 61200305L2 1B ...
Страница 364: ...Section 6 CFG 1 ATLAS 550 System Manual 364 2004 ADTRAN Inc 61200305L2 1B ...
Страница 378: ...Section 7 System Event Logging ATLAS 550 System Manual 378 2004 ADTRAN Inc 61200305L2 1B ...
Страница 388: ...Section 8 ADTRAN Utilities ATLAS 550 System Manual 388 2004 ADTRAN Inc 61200305L2 1B ...
Страница 412: ...Section 9 MIBs ATLAS 550 System Manual 412 2004 ADTRAN Inc 61200305L2 1B ...