Section 4 User Interface Guide
ATLAS 550 System Manual
124
© 2004 ADTRAN, Inc.
61200305L2-1B
M
ODULES
(T1/PRI-2/4) > DS0 A
LARMS
Read security: 5
Displays per-DS0 alarm status. These alarms usually indicate the failure to receive the protocol that has
been configured for the DS0.
M
ODULES
(T1/PRI-2/4) > S
IG
S
TATUS
Read security: 5
Read-only field that indicates signaling of all 24 DS0s. The A/B bits for Rx (receive) and Tx (transmit)
DS0s are shown. Dashes display for those DS0s where robbed bit signaling (RBS) is not being transferred
by the ATLAS 550.
M
ODULES
(T1/PRI-2/4) > P
ERFORMANCE
C
URRENT
Write security: 3; Read security: 5
The performance fields (either current, 15-minute total, or 24-hour total) provide status on key
performance measures as specified in ANSI T1.403 and AT&T TR54016 for the T1/PRI port. Except for
C
LR
, these fields are all read-only. The monitored parameters include the following:
-
No Alarm DS0
D
D Channel Alarm (ISDN)
F
Frame Alarm (packet)
T
TBOP Alarm (packet)
P
PPP Alarm (packet)
P
RT
Displays the port number
C
LR
Clears performance information for the selected port
E
S
Errored Second (ES) is a second with one or more error events OR one or more
Out Of Frame events OR one or more Controlled Slips
B
ES
Bursty Errored Second (BES) is a second with more than one, but less than 320
error events
S
ES
Severely Errored Second (SES) is a second with 320 or more error events OR
one or more Out Of Frame events
S
EFS
Severely Errored Frame Second is a second that contains four consecutive
errored framing patterns.
L
OFC
Loss of Frame Count is a count of seconds in which a valid framing pattern
could not be obtained.
C
SS
Controlled Slip Second
U
AS
Unavailable Second is a second in which the T1 was not available for use (due to
outage, alarms, etc.).
L
CV
Line Code Violation indicates a mismatch in line coding (AMI or B8ZS)
somewhere in the network and is determined by receiving an invalid line
violation (bipolar violation).
Содержание ATLAS 550
Страница 16: ...Table of Contents ATLAS 550 System Manual 16 2004 ADTRAN Inc 61200305L2 1B ...
Страница 24: ...Section 1 System Description ATLAS 550 System Manual 24 2004 ADTRAN Inc 61200305L2 1B ...
Страница 62: ...Section 3 Network Turnup Procedure ATLAS 550 System Manual 62 2004 ADTRAN Inc 61200305L2 1B ...
Страница 308: ...Section 4 User Interface Guide ATLAS 550 System Manual 308 2004 ADTRAN Inc 61200305L2 1B ...
Страница 310: ...Section 5 Detail Level Procedures ATLAS 550 System Manual 310 2004 ADTRAN Inc 61200305L2 1B ...
Страница 320: ...Section 5 DLP 4 ATLAS 550 System Manual 320 2004 ADTRAN Inc 61200305L2 1B ...
Страница 326: ...Section 5 DLP 6 ATLAS 550 System Manual 326 2004 ADTRAN Inc 61200305L2 1B ...
Страница 330: ...Section 5 DLP 7 ATLAS 550 System Manual 330 2004 ADTRAN Inc 61200305L2 1B ...
Страница 348: ...Section 5 DLP 14 ATLAS 550 System Manual 348 2004 ADTRAN Inc 61200305L2 1B ...
Страница 351: ...61200305L2 1B 2004 ADTRAN Inc 351 CONFIGURATION GUIDES CFG 1 Dial Backup for Dedicated T1 Circuits 353 ...
Страница 352: ...Section 6 Configuration Guides ATLAS 550 System Manual 352 2004 ADTRAN Inc 61200305L2 1B ...
Страница 364: ...Section 6 CFG 1 ATLAS 550 System Manual 364 2004 ADTRAN Inc 61200305L2 1B ...
Страница 378: ...Section 7 System Event Logging ATLAS 550 System Manual 378 2004 ADTRAN Inc 61200305L2 1B ...
Страница 388: ...Section 8 ADTRAN Utilities ATLAS 550 System Manual 388 2004 ADTRAN Inc 61200305L2 1B ...
Страница 412: ...Section 9 MIBs ATLAS 550 System Manual 412 2004 ADTRAN Inc 61200305L2 1B ...