ATLAS 550 System Manual
Section 4 User Interface Guide
61200305L2-1B
© 2004 ADTRAN, Inc.
149
M
ODULES
(FXS-4/8) > S
TATUS
> S
TATUS
Read security: 5
Displays the call status of each voice port. This field may display the following:
M
ODULES
(FXS-4/8) > S
TATUS
> R
X
ABCD
Read security: 5
Receive Signaling bits have local significance only, and represent signaling between the ATLAS 550
Controller and the voice port if the port is configured in the
D
IAL
P
LAN
. The bit pattern is formatted
ESF
RBS
.
M
ODULES
(FXS-4/8) > S
TATUS
> T
X
ABCD
Read security: 5
Transmit Signaling bits have local significance only, and represent signaling between the ATLAS 550
Controller and the voice port if the port is configured in the
D
IAL
P
LAN
. The bit pattern is formatted
ESF
RBS
.
I
DLE
The FXS port is in an idle state for LS configurations, and tip is grounded
in GS configurations.
R
ING
G
ROUND
The FXS port has detected ring ground.
O
FF
H
OOK
The FXS port has detected an off hook condition (loop current flowing).
R
EVERSE
B
ATTERY
The FXS port has reversed T/R polarity.
R
INGING
The FXS port is detecting ringing condition on the interface.
T
IP
-O
PEN
The FXS port tip conductor is high impedance. This is an idle condition for
GS trunks.
U
NKNOWN
No information about the FXS port is available.
I
NACTIVE
The port is preconfigured, but the FXS module is not present.
A
VAILABLE
The FXS port is present and available for use.
N
OT
A
VAILABLE
The FXS port is present, but not available for use.
D
ISABLED
The FXS module is present, but the port is not mapped.
T
EST
This generic FXS port test indicator is used when multiple tests are being
run or the test is not a 2W test.
A
CTIVE
Active test is currently running.
O
FF
H
OOK
Active/Reverse Battery test is running, but an off hook condition is
detected.
R
INGING
Ringing test is currently running.
R
EV
. B
AT
Reverse Battery test is currently running.
T
IP
O
PEN
Tip Open test is currently running.
R
ING
GND
Tip Open test is currently running, but ring ground is detected.
D
ISABLED
An active test is running on an FXS port that is not currently mapped.
(-R) T
RIP
Ringing test is currently running, but an off hook condition is detected.
Содержание ATLAS 550
Страница 16: ...Table of Contents ATLAS 550 System Manual 16 2004 ADTRAN Inc 61200305L2 1B ...
Страница 24: ...Section 1 System Description ATLAS 550 System Manual 24 2004 ADTRAN Inc 61200305L2 1B ...
Страница 62: ...Section 3 Network Turnup Procedure ATLAS 550 System Manual 62 2004 ADTRAN Inc 61200305L2 1B ...
Страница 308: ...Section 4 User Interface Guide ATLAS 550 System Manual 308 2004 ADTRAN Inc 61200305L2 1B ...
Страница 310: ...Section 5 Detail Level Procedures ATLAS 550 System Manual 310 2004 ADTRAN Inc 61200305L2 1B ...
Страница 320: ...Section 5 DLP 4 ATLAS 550 System Manual 320 2004 ADTRAN Inc 61200305L2 1B ...
Страница 326: ...Section 5 DLP 6 ATLAS 550 System Manual 326 2004 ADTRAN Inc 61200305L2 1B ...
Страница 330: ...Section 5 DLP 7 ATLAS 550 System Manual 330 2004 ADTRAN Inc 61200305L2 1B ...
Страница 348: ...Section 5 DLP 14 ATLAS 550 System Manual 348 2004 ADTRAN Inc 61200305L2 1B ...
Страница 351: ...61200305L2 1B 2004 ADTRAN Inc 351 CONFIGURATION GUIDES CFG 1 Dial Backup for Dedicated T1 Circuits 353 ...
Страница 352: ...Section 6 Configuration Guides ATLAS 550 System Manual 352 2004 ADTRAN Inc 61200305L2 1B ...
Страница 364: ...Section 6 CFG 1 ATLAS 550 System Manual 364 2004 ADTRAN Inc 61200305L2 1B ...
Страница 378: ...Section 7 System Event Logging ATLAS 550 System Manual 378 2004 ADTRAN Inc 61200305L2 1B ...
Страница 388: ...Section 8 ADTRAN Utilities ATLAS 550 System Manual 388 2004 ADTRAN Inc 61200305L2 1B ...
Страница 412: ...Section 9 MIBs ATLAS 550 System Manual 412 2004 ADTRAN Inc 61200305L2 1B ...