ATLAS 550 System Manual
Section 4 User Interface Guide
61200305L2-1B
© 2004 ADTRAN, Inc.
199
P
ACKET
M
ANAGER
> P
ACKET
E
NDPNTS
> C
ONFIG
> S
UBLINKS
- F
RAME
R
ELAY
Write security: 3; Read security: 5
Contains the configuration parameters for individual sublinks, or PVCs. The following parameters are
available.
CTS O
PTION
Write security: 3; Read security: 5
Configures the Clear To Send (CTS) signal on this interface. CTS may be forced on or can be
configured to be asserted only when Request To Send (RTS) is asserted.
D
ATA
F
ORMAT
Write security: 3; Read security: 5
Configures the data format scheme used on this SLDC endpoint for either NRZ (Non-Return to
Zero) or NRZI (Non-Return to Zero Inverted). Using NRZ configures the Legacy Data Module to
encode using ones and zeroes represented by opposite and alternating high and low voltages. There is
no return to a zero reference voltage between encoded bits. Using NRZI configures the Legacy Data
Module to encode ones with a voltage change and zeroes with no voltage change. NRZI encoding is
also known as transition coding
N
AME
Write security: 3; Read security: 5
User-definable name for the DLCI.
DLCI
Write security: 3; Read security: 5
Local address for each PVC as assigned by the carrier.
QOS
Write security: 3; Read security: 5
Quality of service. These values can be used to assign a guaranteed amount of bandwidth available
for this connection. The sum of all QOS values for the sublink should not exceed the Committed
Information Rate (CIR).
B
URST
Write security: 3; Read security: 5
Sets the burst rate used by this virtual circuit for data traffic. A value of zero means that the burst rate
is not limited. The value is in kilobits/second. If voice traffic is flowing on ANY sublink on the port
carrying THIS sublink, you should enter a value for this setting. Otherwise, leave this field set to
default (zero). If the service provider has supplied a 'Be' value, enter that value in this field. The burst
rate defines the amount that this virtual circuit is allowed to exceed the CIR. If the service provider
has not supplied an excess burst rate, enter the wire speed in this field.
Содержание ATLAS 550
Страница 16: ...Table of Contents ATLAS 550 System Manual 16 2004 ADTRAN Inc 61200305L2 1B ...
Страница 24: ...Section 1 System Description ATLAS 550 System Manual 24 2004 ADTRAN Inc 61200305L2 1B ...
Страница 62: ...Section 3 Network Turnup Procedure ATLAS 550 System Manual 62 2004 ADTRAN Inc 61200305L2 1B ...
Страница 308: ...Section 4 User Interface Guide ATLAS 550 System Manual 308 2004 ADTRAN Inc 61200305L2 1B ...
Страница 310: ...Section 5 Detail Level Procedures ATLAS 550 System Manual 310 2004 ADTRAN Inc 61200305L2 1B ...
Страница 320: ...Section 5 DLP 4 ATLAS 550 System Manual 320 2004 ADTRAN Inc 61200305L2 1B ...
Страница 326: ...Section 5 DLP 6 ATLAS 550 System Manual 326 2004 ADTRAN Inc 61200305L2 1B ...
Страница 330: ...Section 5 DLP 7 ATLAS 550 System Manual 330 2004 ADTRAN Inc 61200305L2 1B ...
Страница 348: ...Section 5 DLP 14 ATLAS 550 System Manual 348 2004 ADTRAN Inc 61200305L2 1B ...
Страница 351: ...61200305L2 1B 2004 ADTRAN Inc 351 CONFIGURATION GUIDES CFG 1 Dial Backup for Dedicated T1 Circuits 353 ...
Страница 352: ...Section 6 Configuration Guides ATLAS 550 System Manual 352 2004 ADTRAN Inc 61200305L2 1B ...
Страница 364: ...Section 6 CFG 1 ATLAS 550 System Manual 364 2004 ADTRAN Inc 61200305L2 1B ...
Страница 378: ...Section 7 System Event Logging ATLAS 550 System Manual 378 2004 ADTRAN Inc 61200305L2 1B ...
Страница 388: ...Section 8 ADTRAN Utilities ATLAS 550 System Manual 388 2004 ADTRAN Inc 61200305L2 1B ...
Страница 412: ...Section 9 MIBs ATLAS 550 System Manual 412 2004 ADTRAN Inc 61200305L2 1B ...