Section 5 DLP-15
ATLAS 550 System Manual
350
© 2004 ADTRAN, Inc.
61200305L2-1B
1. Connect to the ATLAS 550 using either the
ETHERNET
,
ADMIN
, or
CRAFT
interfaces.
If you are not already connected to the unit’s
ADMIN
or
CRAFT
interface, either with a VT100
compatible terminal or with a PC running VT100 emulation software, use the procedure in DLP-2,
Logging in to the ATLAS 550
, to connect to the
ADMIN
or
CRAFT
interface.
Alternatively, if the unit is part of a management cluster connected to the local network, you may use a
PC connected to the network to Telnet into the unit. To connect to the
ETHERNET
interface, use the
procedures in DLP-3,
Setting IP Parameters for the ATLAS 550
, and in DLP-4,
Verifying
Communications Over an IP LAN
.
2. Log in to the unit using the read-write password (see DLP-2,
Logging in to the ATLAS 550
, for details).
1. Go to the
S
YSTEM
C
ONFIG
menu and press the right-arrow key to access the right-pane menus. Select
the
A
LARM
R
ELAY
T
HRESHOLD
menu and choose the appropriate threshold level. The
A
LARM
R
ELAY
will set for this threshold and all other alarms of greater importance. Refer to Section 7,
System Event
Logging
of this user manual for a listing of all alarms and levels of importance.
1. Go to the
S
YSTEM
C
ONFIG
menu and press the right-arrow key to access the right-pane menus. Then,
select the
E
VENT
L
OGGING
menu and press <Enter>. Once in the
E
VENT
L
OGGING
menu, press the
right-arrow key to access the right-pane menus.
2. From the
E
VENT
L
OGGING
menu, select the
E
XTERNAL
I
NPUT
menu and set it to the same value as the
A
LARM
R
ELAY
T
HRESHOLD
. Any event on the
A
LARM
M
ONITOR
will now be logged in the
E
VENT
L
OG
and
set the
A
LARM
R
ELAY
.
1. Go to the
S
YSTEM
C
ONFIG
menu and press the right-arrow key to access the right-pane menus. Then,
select the
A
LARM
R
ELAY
R
ESET
field and press <Enter>.
Perform the following steps below in the order listed:
Configuring the Alarm Relay
Setting the threshold to
N
ORMAL
will not set the
A
LARM
R
ELAY
for
N
ORMAL
events. No
N
ORMAL
events set the
A
LARM
R
ELAY
.
(Optional) Configuring the Alarm Monitor for External Alarms
Clearing the Alarm Relay Remotely
Clear the
A
LARM
R
ELAY
locally by pressing the
ACO
switch on the front panel.
Содержание ATLAS 550
Страница 16: ...Table of Contents ATLAS 550 System Manual 16 2004 ADTRAN Inc 61200305L2 1B ...
Страница 24: ...Section 1 System Description ATLAS 550 System Manual 24 2004 ADTRAN Inc 61200305L2 1B ...
Страница 62: ...Section 3 Network Turnup Procedure ATLAS 550 System Manual 62 2004 ADTRAN Inc 61200305L2 1B ...
Страница 308: ...Section 4 User Interface Guide ATLAS 550 System Manual 308 2004 ADTRAN Inc 61200305L2 1B ...
Страница 310: ...Section 5 Detail Level Procedures ATLAS 550 System Manual 310 2004 ADTRAN Inc 61200305L2 1B ...
Страница 320: ...Section 5 DLP 4 ATLAS 550 System Manual 320 2004 ADTRAN Inc 61200305L2 1B ...
Страница 326: ...Section 5 DLP 6 ATLAS 550 System Manual 326 2004 ADTRAN Inc 61200305L2 1B ...
Страница 330: ...Section 5 DLP 7 ATLAS 550 System Manual 330 2004 ADTRAN Inc 61200305L2 1B ...
Страница 348: ...Section 5 DLP 14 ATLAS 550 System Manual 348 2004 ADTRAN Inc 61200305L2 1B ...
Страница 351: ...61200305L2 1B 2004 ADTRAN Inc 351 CONFIGURATION GUIDES CFG 1 Dial Backup for Dedicated T1 Circuits 353 ...
Страница 352: ...Section 6 Configuration Guides ATLAS 550 System Manual 352 2004 ADTRAN Inc 61200305L2 1B ...
Страница 364: ...Section 6 CFG 1 ATLAS 550 System Manual 364 2004 ADTRAN Inc 61200305L2 1B ...
Страница 378: ...Section 7 System Event Logging ATLAS 550 System Manual 378 2004 ADTRAN Inc 61200305L2 1B ...
Страница 388: ...Section 8 ADTRAN Utilities ATLAS 550 System Manual 388 2004 ADTRAN Inc 61200305L2 1B ...
Страница 412: ...Section 9 MIBs ATLAS 550 System Manual 412 2004 ADTRAN Inc 61200305L2 1B ...