Section 4 User Interface Guide
ATLAS 550 System Manual
242
© 2004 ADTRAN, Inc.
61200305L2-1B
D
EDICATED
M
APS
(N
X
T1 HSSI) > C
REATE
/E
DIT
M
APS
> C
ONNECTS
> T
O
/F
ROM
C
ONFIG
Write security: 3; Read security: 5
Specifies the configuration for the
T
O
/F
ROM
connection. The following selection applies to the NxT1 HSSI
and NxT1 HSSI/V.35 Option Modules when connected to a port on a T1 Module. This is the only valid
application for the NxT1 HSSI and NxT1 HSSI/V.35 Option Modules.
DS0 S
ELECTION
Write security: 3; Read security: 5
Defines DS0s for the T1 port. Use this field to define the DS0s for this connection.
For the NxT1 HSSI and NxT1 HSSI/V.35 Option Modules, any entry in the DS0 selection
field that is less than 24 DS0s is disregarded. The NxT1 HSSI and NxT1 HSSI/V.35 Option
Modules requires the use of all 24 DS0s on a T1 for proper operation.
DS0
S
A
VAILABLE
Write security: 3; Read security: 5
Indicates which DS0s of the T1 are assigned. DS0 assignment is based on the following items:
D
IGIT
0-9
This DS0 is available. The digit that displays in this field represents the
last digit of the DS0 number.
*
This DS0 has been requested for this connection, but the DS0 is not yet
activated for this port.
!
This DS0 is used by this port in this connection and is currently
activated.
S
This DS0 is used in the switched
D
IAL
P
LAN
.
S
This DS0 is used in the switched
D
IAL
P
LAN
and conflicts with this
connection.
N
This DS0 is already used in this
D
EDICATED
M
AP
.
N
This DS0 is already used in this
D
EDICATED
M
AP
and conflicts with this
connection.
T1 T
ROUBLE
C
ODE
S
ERVICE
Write security: 3; Read security: 5
Sets known values in the signaling bits and the data field for outgoing DS0s which are
cross-connected to a T1 port experiencing alarms.
The trunk conditioning process consists of a 2.5 second transmission (indicating call termination),
followed by a continuous transmission signaling the final condition as chosen by the user. This
selection is only valid for T1 ports having
RBS
set to
O
N
.
This option defines the type of signaling being used on the trunk:
E&M
,
LS/GS N
ETWORK
OR
U
SER
,
SW56
, or
C
USTOM
.
Содержание ATLAS 550
Страница 16: ...Table of Contents ATLAS 550 System Manual 16 2004 ADTRAN Inc 61200305L2 1B ...
Страница 24: ...Section 1 System Description ATLAS 550 System Manual 24 2004 ADTRAN Inc 61200305L2 1B ...
Страница 62: ...Section 3 Network Turnup Procedure ATLAS 550 System Manual 62 2004 ADTRAN Inc 61200305L2 1B ...
Страница 308: ...Section 4 User Interface Guide ATLAS 550 System Manual 308 2004 ADTRAN Inc 61200305L2 1B ...
Страница 310: ...Section 5 Detail Level Procedures ATLAS 550 System Manual 310 2004 ADTRAN Inc 61200305L2 1B ...
Страница 320: ...Section 5 DLP 4 ATLAS 550 System Manual 320 2004 ADTRAN Inc 61200305L2 1B ...
Страница 326: ...Section 5 DLP 6 ATLAS 550 System Manual 326 2004 ADTRAN Inc 61200305L2 1B ...
Страница 330: ...Section 5 DLP 7 ATLAS 550 System Manual 330 2004 ADTRAN Inc 61200305L2 1B ...
Страница 348: ...Section 5 DLP 14 ATLAS 550 System Manual 348 2004 ADTRAN Inc 61200305L2 1B ...
Страница 351: ...61200305L2 1B 2004 ADTRAN Inc 351 CONFIGURATION GUIDES CFG 1 Dial Backup for Dedicated T1 Circuits 353 ...
Страница 352: ...Section 6 Configuration Guides ATLAS 550 System Manual 352 2004 ADTRAN Inc 61200305L2 1B ...
Страница 364: ...Section 6 CFG 1 ATLAS 550 System Manual 364 2004 ADTRAN Inc 61200305L2 1B ...
Страница 378: ...Section 7 System Event Logging ATLAS 550 System Manual 378 2004 ADTRAN Inc 61200305L2 1B ...
Страница 388: ...Section 8 ADTRAN Utilities ATLAS 550 System Manual 388 2004 ADTRAN Inc 61200305L2 1B ...
Страница 412: ...Section 9 MIBs ATLAS 550 System Manual 412 2004 ADTRAN Inc 61200305L2 1B ...